The activation of this parameter (setting other than OFF) forces the
permanent display of SCREED DRYING and deactivates all other
functions on the control unit.
When floor drying is active on a circuit, all other circuits (e.g. DHW)
are shut down. The use of this function is only possible on circuits B
and C.
STOP DRYING TEMP
A
START DRYING TEMP
Z
Today
E
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
For example
A
STOP DRYING TEMP: 47 °C
Z
START DRYING TEMP: 20 °C
NB DAYS DRYING
R
Normal regulation (End of drying)
T
Heating temperature setting (°C)
Y
Every day at midnight (00:00): the set point (START
DRYING TEMP) is recalculated and the remaining number
of days (NB DAYS DRYING) is decremented.
n ROOM S.INFL
Used to adjust the influence of the room sensor on the water
temperature for the circuit concerned.
No influence (remote control fitted in a location with no influence)
0
Slight influence
1
Average influence (recommended)
3
10 Room thermostat type operation
n NIGHT
This parameter is displayed if at least one circuit does not
include a room sensor.
For circuits without a room sensor:
4 NIGHT :DEC. (Reduced): The reduced temperature is maintained
during reduced periods. The circuit pump operates constantly.
AWHP MIT-IN iSystem
24/09/2012 - 300027606-001-01