DeDietrich AWHP 6 MR Installation And Service Manual page 56

Air / water heat pump
Hide thumbs Also See for AWHP 6 MR:
Table of Contents

Advertisement

4. Installation
Settings to be made for this type of installation
Parameters
Access
INSTALLATION Installer level
#SYSTEM menu
Installer level
(1)
O.PUMP A
#SYSTEM menu
Installer level
(1)
CIRC. A:
#SYSTEM menu
PUMP MIT/MHR Installer level
#SYSTEM menu
Installer level
(1)
CIRC. B:
#SYSTEM menu
CIRC.CURVE A Installer level
#SECONDARY INSTAL.P menu
CIRC.CURVE B Installer level
#SECONDARY INSTAL.P menu
(1) The parameter is only displayed if INSTALLATION parameter is set to EXTENDED
55
Connect the outside temperature sensor.
E
Connect the 3-way valve motor (circuit B) and the circuit
R
B flow sensor.
Connect the heating pump (Circuit B).
T
Connect a safety thermostat if the heating circuit is for
Y
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Connect the DHW sensor (Package AD212).
U
Connect the DHW tank anode.
I
CAUTION
4
4
Not used: Do not connect anything to the terminal block.
O
Connect the motor on the DHW reversal valve.
P
a
Connect the domestic hot water looping pump to the M
outlet.
Connect the BUS cable between the outside module and
z
the terminal block on the inside module.
See chapter: ¼ "Connecting the communication
cable between the inside and outside modules", page
45.
Settings to be made See chapter
¼ "Displaying the parameters in extended
EXTENDED
mode", page 78
¼ "Setting the parameters specific to the
DHW LOOP
installation", page 78
¼ "Setting the parameters specific to the
DIRECT
installation", page 78
¼ "Setting the parameters specific to the
CIRC. A:
installation", page 78
¼ "Setting the parameters specific to the
3WV
installation", page 78
¼ "Professional settings", page 91
1.5
¼ "Professional settings", page 91
0.7
AWHP MIT-IN iSystem
If the tank is fitted with a Titan Active
System® impressed current anode,
connect the anode to the inlet (+ TA on the
anode, - on the tank).
If the tank is not fitted with an impressed
current anode, put the simulation
connector in place (delivered with the DHW
sensor - package AD212).
24/09/2012 - 300027606-001-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents