4. Installation
Settings to be made on the inside module for this type of installation
Parameters
Access
INSTALLATION Installer level
#SYSTEM menu
Installer level
(1)
O.PUMP A
#SYSTEM menu
Installer level
(1)
CIRC. A:
#SYSTEM menu
PUMP MIT/MHR Installer level
#SYSTEM menu
Installer level
(1)
CIRC. B:
#SYSTEM menu
CIRC.CURVE A Installer level
#SECONDARY INSTAL.P menu
CIRC.CURVE B Installer level
#SECONDARY INSTAL.P menu
Installer level
HP BUS
#PRIMARY INSTAL.P menu
Installer level
BACKUP TYPE
#PRIMARY INSTAL.P menu
(1) The parameter is only displayed if INSTALLATION parameter is set to EXTENDED
51
Connect a safety thermostat if the heating circuit is for
U
underfloor heating: Remove the bridge. Connect the wires
from the safety thermostat to the connector.
Not used: Do not connect anything to the terminal block.
I
Connect the BUS cable between the outside module and
O
the terminal block on the inside module.
Connect the outlet AD 199 sensor (Circuit B).
P
Connect the heating pump and the K relays to the AL1
a
connector on the PCU PCB.
Connect the boiler's room thermostat to the AL2
z
connector on the PCU PCB.
Settings to be made See chapter
¼ "Displaying the parameters in extended
EXTENDED
mode", page 78
¼ "Setting the parameters specific to the
CH.PUMP A
installation", page 78
¼ "Setting the parameters specific to the
DIRECT
installation", page 78
¼ "Setting the parameters specific to the
CIRC. A:
installation", page 78
¼ "Setting the parameters specific to the
3WV
installation", page 78
¼ "Professional settings", page 91
1.5
¼ "Professional settings", page 91
0.7
¼ "Professional settings", page 91
TOR
¼ "Professional settings", page 91
/H
Setting the back-up boiler
The setting of the back-up boiler depends on its type of control panel.
4 Diematic 3
Set the following installer settings on the boiler control panel:
- I.TEL:: THERM A
- HCZP D / HCZP N: same value as the parameter HEAP
MAX: on the Diematic iSystem control panel on the MIT.
- CIRC.CURVE A: 0.0
- OUT.ANTIFREEZE: -8 °C
Access to parameters:
- Press the - key for 5 seconds.
- Press the ( key 2 times.
- Use key ' to select the desired parameter.
4 SVmatic
Heating temperature setting = HEAP MAX:.
4 B control panel
AWHP MIT-IN iSystem
24/09/2012 - 300027606-001-01