15.3

Grinders wear alert programming

With this function, the machine displays an alert
relative to grinders wear and replacement, according to
the kg of coffee used.
• Press "Counters" (see previous chapter); after a short
time the main screen appears.
• Scroll through the screens with the ar-
rows () or (), until you see the screen
below:
Counters
Wear ABD Blades
Grinded
Limit
Grinded
Total weight in kg of coffee used since the last reset.
Threshold to be reached in kg of coffee, for signaling
Limit
grinders wear.
To change the amount in kg, press "Limit" and set the
desired value. The available range is: 0 ÷ 2000 kg.
i
By setting the threshold for "GRINDERS WEAR" to
0, the system will not display any alerts.
Counters
After setting the threshold limit of coffee in kg, you
must set each beverage button and give them the correct
weight of ground coffee used.
Press () and move to the screen below.
54
Select the dose key "K1", and in the next screen, enter
the amount in grams of ground coffee for the dose in
programming.
Repeat the previous step up to the setting of all the
dose keys.
The available range is: 0 ÷ 22 g.
After this operation, the counter will be incremented
by the dose set for each drink with every dispensing of
coffee during use.
k1
k3
k2
Key correspondence - displayed value.
Example of setting:
k1 g.07
(Single espresso)
k2 g.14
(Double espresso)
k3 g.07
(Medium single)
kC g.07
(Continuous)
Upon reaching the amount of kilograms set as the
threshold, the system will display a message, reminding
the user to perform the replacement of the grinders of
the coffee grinder.
Reset
To reset the executed cycles counter proceed as
follows:
• move to the "Grinders Wear" screen;
• press the reset key (
• in the next screen answer "Yes";
• the ground coffee kg count will restart from 0.
i
The system only works if the machine is paired with
only one grinder.
i
Setting one or more dose keys to 0, the count for
those keys will not be performed.
k5
P
rog
S
top
k4
k6
kC
k4 g.14
(Medium double)
k5 g.07
(Single long)
k6 g.14
(Double long)
);