Astoria Plus4YouTS Use And Maintenance Manual page 69

Espresso coffee maker
Hide thumbs Also See for Plus4YouTS:
Table of Contents

Advertisement

Fuse
F1
Fuse 5x20 delayed by 6.3A
F2
Fuse5x20FF super rapid by 10A
F3
Fuse5x20 FF super rapid by 10A
F4
Fuse5x20FF super rapid by 10A
F5
Fuse 5x20 FF super rapid by 10A
F6
Fuse 5x20 FF super rapid by 10A
F7
Fuse 5x20 delayed by 1A
F8
Fuse 5x20 FF super rapid by 10A
F9
Fuse 5x20 delayed by 1A
F10 Fuse 5x20 delayed by 6.3A
Off On SW1 Switch
1   Not used. leave on OFF mode.
2   Reserve.
3   Reserve
4   Reserve.
5   Reserve.
6   ON = rinse active for 3 secs. PROG./STOP button.
ON = excludes the automatic control of the services boiler
7  
temperature
8   ON = Pre-infusion active
LED
Description
DL1
Front Led
DL2
Not managed
DL3
Cup heater
DL4
Heating element control boiler group 4
DL5
Heating element control boiler group 2
DL6
Heating element control boiler group 3
DL7
Heating element control boiler group 1
DL8
group 1 heating element
DL9
group 3 heating element
DL10
group 2 heating element
DL11
group 4 heating element
DL12
services 1 boiler heating element
DL13
group 1 volumetric counter
DL14
group 2 volumetric counter
DL15
group 3 volumetric counter
DL16
group 4 volumetric counter
DL17
services 2 boiler heating element
+5V
+5V Power supply
+9V
+9V Power supply
+12V
+12V Power supply
+24V
+24V Power supply
Technical manual
Description
Protects: from RL1 to RL13
Protects: group coffee boiler heating element 4
Protects: group coffee boiler heating element 2
Protects: group coffee boiler heating element 3
Protects: group coffee boiler heating element 1
Protects : coffee boiler heating element group 1 e 3
Protects: transformer's double winding
Protects : coffee boiler heating element group 2 and 4
Protects: services boiler heating element group 1 and 2
Protects: +24V Power supply
Off On SW2 Switch
9   ON = 6 doses keyboard.
10   ON = rinse active for 3 secs. dose buttons.
11   ON = Active Credit / Debit.
12   ON = Reset machine life cycle
13   ON = Continuous disabled.
14   ON = NTC probe
15   ON = Serial communication active.
ON = MICRO-Processor programming.
16  
OFF = Machine service enabled
Jumper Description
JP1
Not managed
JP2
Aux
JP3
Aux
JP4
TX-RX signal inversion
JP5
TX-RX signal inversion
Relay
Description
RL1
Pump
RL2
Solenoid valve group 1
RL3
Solenoid valve group 3
RL4
Solenoid valve group 2
RL5
Solenoid valve group 4
RL6
Boiler filling solenoid valve
RL7
Hot water mix solenoid valve
RL8
Tea solenoid valve 1
RL9
Autosteamer steam solenoid valve
RL10
Air solenoid valve
RL11
Tea solenoid valve 2
RL12
Reserve 2
RL13
Reserve 1
69

Advertisement

Table of Contents
loading

Table of Contents