Phone Line Connections; Alternative Communications Media (Acm) Connections - Honeywell ADEMCO VISTA-48D Installation And Setup Manual

Table of Contents

Advertisement

Installation Instructions

Phone Line Connections

Connect incoming phone line and handset wiring to the
main terminal block (via an RJ31X jack) as shown in the
Summary of Connections diagram at the back of this
manual. Wire colors represent the colors of the cable to
the RJ31X jack.
Alternative Communications Media (ACM)
Connections
Connect the data in/data out terminals and voltage input
terminals of the ACM to the control's keypad connection
points.
Set the ACM's address to "03" following the instructions
provided with the ACM.
Audio Alarm Verification Connections
(AAV, "Listen-In")
Refer to the connection diagram below.
Connections use one of the on-board triggers.
UL
UL installations using the AAV feature must use the
ADEMCO UVCM module (part of the ADEMCO UVS
system).
Suggested AAV Module:
ADEMCO UVS (shown) or Eagle 1250
NOTE:
REFER TO UVCM MODULE
INSTRUCTIONS FOR
CONNECTIONS TO AUDIO
SPEAKERS AND MICROPHONE.
2-14
AUXILIARY
AUDIO LEVEL
ADJUSTMENT
TRIM POT
UVCM
MODULE
SWITCH
SWITCH
BANK 1
BANK 2
1 = OFF
1 = ON
2 = ON
2 = OFF
3 = OFF
3 = OFF
FALLING VOICE TRIG
4 = OFF
4 = ON
5 = OFF
5 = ON
6 = OFF
6 = ON
7 = OFF
7 = ON
8 = ON
8 = ON
Figure 14. Connection of AAV Unit
Notes
• If you are using an Audio Alarm Verification
(AAV) unit, refer to Audio Alarm Verification
(AAV) section for special wiring connections.
CAUTION: To reduce the risk of fire, use only
0.6mm O.D. or larger telecommunication line cord
for phone line connections.
Notes
• Use compatible ACMs (e.g., 7845i, 7845C/7835C
[in Latin America], AI4164RS, AI4164ETH).
Notes
• Set field *91 for AAV and program the appropriate
output (output 17 or 18) using *80 Menu mode
(select zone type "60").
• For voice session monitoring, connect an EOLR
zone to UVCM module terminals 6 & 7, and
program the zone as zone type 81 (*56 Menu
mode).
E.g., Using output 18 for the trigger, program an
output function in *80 Menu mode as:
ZT = 60, P = 0, Action = 1, Device = 18
5
CONTROL
4
5
GND
+12VDC IN
TRIGGER
CONNECTOR
ZONE
TERMINALS
21
22
23
24 25
EOL
RING
TIP
RED (R)
GREEN (T)
GREY (R)
BROWN (T)
OPTIONAL
MONITORING ZONE
CONNECTION
(USE ZONE TYPE 81)
TO
PREMISES
HANDSET
EARTH
GROUND
RJ31X
INCOMING
PHONE LINE