Probe-Scsi And Probe-Scsi-All Diagnostic - Sun Microsystems Ultra 2 series Service Manual

Hide thumbs Also See for Ultra 2 series:
Table of Contents

Advertisement

CODE EXAMPLE 4-3
Type any key to stop.
..
ok
4.6.4

Probe-SCSI and Probe-SCSI-All Diagnostic

The probe-SCSI diagnostic transmits an inquiry command to internal and external
SCSI devices connected to the system unit on-board SCSI interface. If the SCSI
device is connected and active, the target address, unit number, device type, and
manufacturer name is displayed. The probe-SCSI-all diagnostic transmits an inquiry
command to SCSI devices connected to the system SCSI host adapters. The first
identifier listed in the display is the SCSI host adapter address in the system device
tree followed by the SCSI device identification data.
The probe-SCSI diagnostic is initialized by typing the probe-scsi command at the
ok prompt and the probe-SCSI-all diagnostic is initialized by typing the
probe-scsi-all command at the ok prompt. The following code example
identifies the probe-SCSI diagnostic output message.
probe-SCSI-all diagnostic output message.
CODE EXAMPLE 4-4
{0} ok probe-scsi
Target 0
Unit 0
Target 1
Unit 0
Target 6
Unit 0
{0} ok
CODE EXAMPLE 4-5
{0} ok probe-scsi-all
probe-scsi-all?
{0} ok probe-scsi-all
/sbus@1f,0/SUNW,fas@e,8800000
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Watch-Net-All Diagnostic Output Message (Continued)
Probe-SCSI Diagnostic Output Message
Disk
QUANTUM VK2275J SUN2.1G1210
Disk
SEAGATE ST32171W SUN2.1G8254
Removable Read Only device
Probe-SCSI-All Diagnostic Output Message
CODE EXAMPLE 4-5
TOSHIBA XM5701TASUN12XCD0997