CODE EXAMPLE 3-1
1>...... Processor 1 is in slave-wait phase...
0>Cross Calls Test
0>
Cross Calls Test
0>Cache Coherency Test
0>
Multi-Processor Cache Coherence Test
0>
<< POST COMPLETE >>
0>**Entering OBP (3b)
Power On Selftest Completed
3.4.2

Diag-Level NVRAM Variable Set to min

When the diag-level NVRAM parameter is set to min, POST enables an abbreviated
set of diagnostic-level tests. This mode requires approximately 2 minutes to
complete with a dual CPU configuration and 640 Mbytes of memory installed, or
approximately 45 seconds to complete with a single CPU configuration and 640
Mbytes of memory installed. The following code example identifies a serial port A
POST output with the diag-level NVRAM variable set to min.
CODE EXAMPLE 3-2
Button Power ON
Master CPU online
Master Version: 0000.0000.2200.1040
Slave Version: 0000.0000.2200.1040
CPU E$(M) 0000.0000.0010.0000 (S) 0000.0000.0010.0000
Button Power ON
Master CPU online
Master Version: 0000.0000.2200.1040
Slave Version: 0000.0000.2200.1040
CPU E$(M) 0000.0000.0010.0000 (S) 0000.0000.0010.0000
Probing keyboard Done
%o0 = 0000.0000.0000.2001
Executing Power On SelfTest