Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
GE Manuals
Laboratory Equipment
AKTA avant
Operating instructions manual
Unscrew The Two White Plastic Screws Located Below Each Pump Head By Hand. Pull The Plastic Connectors To The Sides To Release The Inlet Manifold; Disconnect The Tubing Of The Pump Piston Rinsing System - GE AKTA avant Operating Instructions Manual
Preparative chromatography system
Hide thumbs
Also See for AKTA avant
:
User manual
(538 pages)
,
Getting started
(134 pages)
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
page
of
202
Go
/
202
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
Disassemble the pump head
Step
1
2
3
4
5
ÄKTA avant Operating Instructions 29101556 AB
7.3 Replace pump piston seal, O-ring, and rinse membrane of Pump P9-S
Action
Make sure that no run is in progress on the instrument.
Disconnect the tubing from the pump head, and disconnect the pump inlet
tubing.
Unscrew the two white plastic screws located below each pump head by
hand. Pull the plastic connectors to the sides to release the inlet manifold.
Disconnect the tubing of the pump piston rinsing system.
Unscrew one of the two screws of the pump head using a hex wrench. Un-
screw the second screw, and at the same time push firmly on the front of
the rinse chamber to compensate for the pressure of the piston return spring.
7 Maintenance
165
Table of
Contents
Previous
Page
Next
Page
1
...
164
165
166
167
Show Quick Links
Quick Links:
Calibrate the Ph Monitor
System Specifications
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for GE AKTA avant
Laboratory Equipment GE AKTA avant User Manual
(538 pages)
Laboratory Equipment GE AKTAavant Getting Started
(134 pages)
Laboratory Equipment GE ÄKTA start Maintenance Manual
(12 pages)
Laboratory Equipment GE ÄKTA start Manual
(12 pages)
Laboratory Equipment GE AKTA start Maintenance Manual
(164 pages)
Laboratory Equipment GE ÄKTAprocess Site Preparation Manual
(17 pages)
Laboratory Equipment GE AKTAprocess Operating Instructions Manual
(180 pages)
Laboratory Equipment GE ÄKTApilot Site Preparation Manual
(14 pages)
Laboratory Equipment GE ÄKTAcrossflow Site Preparation Manual
(14 pages)
Laboratory Equipment GE AKTApure User Manual
(522 pages)
Laboratory Equipment GE akta pure Operating Instructions Manual
(160 pages)
Laboratory Equipment GE ÄKTA pure Operating Instructions Manual
(142 pages)
Laboratory Equipment GE AKTAprime plus Operating Instructions Manual
(68 pages)
Laboratory Equipment GE AKTA GO Operating Instructions Manual
(117 pages)
Laboratory Equipment GE AKTA ready Operating Instructions Manual
(227 pages)
Laboratory Equipment GE AKTA Prime Plus Instructions
Uv lamp exchange (4 pages)
Related Content for GE AKTA avant
AKTApure Clean The Pump Head Check Valves
GE AKTApure
AKTA avant Clean Pump Head Check Valves
GE AKTA avant
LOGIQ S8 Replacement Of Monitor And Lcd Arm Plastic Covers
GE LOGIQ S8
AKTA pilot 600 Inlet Valves
GE AKTA pilot 600
AKTAprocess Cip / Axichrom Manifold
GE AKTAprocess
AKTA ready Äkta Ready Gradient Pump
GE AKTA ready
AKTA GO Prepare The Pump Rinsing System
GE AKTA GO
AxiChrom 50 Wetting Instructions For Plastic Bed Supports
GE AxiChrom 50
Ettan IPGphor 3 Use The Ettan Ipgphor Cup Loading Manifold
GE Ettan IPGphor 3
ÄKTA pure Prepare The Pump Rinsing System
GE ÄKTA pure
Monitor UV-900 Cleaning The Flow Cell And Optical Fiber Connectors
GE Monitor UV-900
ImageQuant LAS 4000 Changing The Uv Transilluminator Or White Light Table
GE ImageQuant LAS 4000
ImageQuant LAS 4000 Attaching The Camera Head
GE ImageQuant LAS 4000
AKTA start Pump
GE AKTA start
akta pure Inlet Valve
GE akta pure
ReadyToProcess WAVE 25 Readytoprocess Pump 25
GE ReadyToProcess WAVE 25
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL