Technical specifications

8.4 Technical specifications
8.4
Technical specifications
8.4.1

General technical specifications

Note
Applicability of technical specifications
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The fan cover and filter pad are installed.
• The device is closed.
Order numbers
Dimensions
Weight
Supply voltage (V
Input current
Frequency
Transient voltage interruption
Power consumption, at maximum
configuration
Power loss, heat emission
Current delivery (DC)
100
6AG4104-3....-.... (for details, refer to the ordering documentation)
433.5 × 176.5 × 445.5 (W × H × D in mm)
You can find detailed information on dimensions in the section
"Dimension drawing of the device (Page 98)".
16 to 23 kg, depending on configuration
)
Simple power supply:
N
100 V AC to 240 V AC (-15%, +10%)
Redundant power supply:
2 × 100 V AC to 240 V AC (-15%, +10%)
Continuous current at 100 V: ≤ 6 A
Continuous current at 240 V: ≤ 3 A
Simple power supply:
At startup ≤ 80 A for 3.6 ms
Redundant power supply:
At startup ≤ 210 A for 1.65 ms for each module
50 to 60 Hz
Minimum 47 Hz to maximum 63 Hz, sinusoidal
20 ms at 93 V, ≤ 10 events per hour, recovery time ≥ 1 s
With 230 W secondary:
Simple power supply:
≤ 290 W at 80% efficiency
Redundant power supply:
≤ 290 W at 80% efficiency
290 W = 290 J/s = 0.28 BTU/s
+5 V/26 A, +3.3 V/24 A; in total 190 W permitted
+12 V/15 A; +12 V/15 A;
–12 V/0.2 A; +5 Vaux/2 A
The total sum of all voltages is max. 230 W.