Technical specifications

8.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The device is closed.
• The I/O devices fulfill the requirements for the respective area of application (interference
emission according to EN 61000-6-3 / IEC 61000-6-3, interference immunity according to
EN 61000-6-2 / IEC 61000-6-2).
8.2

General technical specifications

See the note under "Validity of the technical specifications (Page 74)".
Article number
Dimensions
Base device:
Device with 2x expansion:
Weight
Base device:
Device with 2x expansion:
Supply voltage DC
Input current DC
Short-term voltage interruption in
accordance with Namur
Max. power consumption
Noise emission
Degree of protection
Quality assurance
74
6AG4142-.....-.... (for details, refer to the ordering documenta-
tion)
262 x 133 x 63 (W × H × D in mm)
262 x 133 x 114 (W × H × D in mm)
Approx. 2.3 kg
Approx. 2.7 kg
Nominal 24 V DC (-20% / + 20%), SELV
1
Continuous current up to 4 A
Max. 20 ms (at 20.4 V)
(max. 10 events per hour; recovery time of at least 1 s)
67.5 W (at 24 V)
< 40 dB(A) according to DIN 45635-1
IP 20 according to IEC 60529
In accordance with ISO 9001
1
2
Operating Instructions, 07/2022, A5E50715883-AA
8
SIMATIC IPC BX-39A