Technical specifications

8.1

Applicability of technical specifications

Note
The following technical specifications only apply under the following conditions:
• The device is in good working order.
• The device is closed.
• The I/O devices fulfill the requirements for the respective area of application (interference
emission according to EN 61000-6-3 / IEC 61000-6-3, interference immunity according to
EN 61000-6-2 / IEC 61000-6-2).
8.2

General technical specifications

See the note under "Validity of the technical specifications (Page 68)".
Article number
Dimensions
Base device:
Device with 1x expansion:
Weight
Base device:
Device with 1x expansion:
Supply voltage DC
Input current DC
Short-term voltage interruption in
accordance with Namur
Max. power consumption
Noise emission
Degree of protection
Quality assurance
68
6AG4152-.....-.... (for details, refer to the ordering documenta-
tion)
255 x 133 x 75 (W × H × D in mm)
255 x 133 x 103 (W × H × D in mm)
Approx. 2.5 kg
Approx. 2.7 kg
Nominal 12/24 V DC, 9-36 V DC
Continuous current up to 10 A
Max. 20 ms (at 12 V)
Max. 20 ms (at 20.4 V)
(max. 10 events per hour; recovery time of at least 1 s)
80 W (at 9 V)
79 W (at 12 V)
78 W (at 24 V)
76 W (at 36 V)
< 40 dB(A) according to DIN 45635-1
IP 20 to IEC 60529
1
In accordance with ISO 9001