Connecting The Power Supply - Siemens SIMATIC IPC547E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC547E:
Table of Contents

Advertisement

Installing and connecting the device
3.3 Connecting the device
Procedure
3.3.4

Connecting the power supply

Note before you connect the device
Injury to persons or damage to property when operated on an incorrect power supply
system
If you connect the device to an unsuitable power supply, the device receives voltages and
currents that are too high or too low.
Injuries to persons, malfunctions or a damage to the device can result.
Note the following information regarding the power supply system:
• The permitted nominal voltage of the device must correspond to the local mains voltage.
• Do not operate the device via non-grounded or impedance-grounded networks (IT
• Operate the device only in grounded power networks (TN networks in accordance with
Note
Operation with uninterruptible power supply
An uninterruptible AC power supply (UPS) must be used when this device is operated with a
PFC (Power Factor Correction) circuit that supplies a sinusoidal output voltage in normal and
buffer mode.
UPS characteristics are described and classified in the standards EN 50091-3 or
IEC 62040-3. Devices with sinusoidal output voltage in the normal and buffered mode are
identified with the classification "VFI-SS-...." or "VI-SS-....".
Note
The power supply of the device contains a PFC (Power Factor Correction) circuit to conform
to the EMC directive.
36
WARNING
networks).
VDE 0100, Part 300 or IEC 60364-3).
1. Connect the identified equipotential bonding
connection to the protective conductor of the
control cabinet in which the device is
installed.
The minimum cross-section of the
equipotential bonding line is 2.5 mm
Operating Instructions, 09/2013, A5E32317120-AA
.