Technical specifications

8.1

General specifications

Order number
Dimensions
Weight
Supply voltage (V
Input current
Inrush current
Line voltage frequency
Power consumption
Noise emission
Degree of protection
Dust protection
Not evaluated by UL
1
Note
Dimensioning of fuses in higher-level plant circuits
A fuse with a fuse rating according to the "Input current" row of the previous table is
integrated in the power supply unit of the IPC. Pulse currents during startup are also taken
into consideration due to the "time-lag" fuse type. In the case of a fault, this fuse ensures the
correct separation of the device from the power supply.
We recommend dimensioning the fuse of the higher-level power supply circuit with at least
the internal fuse rating of the IPC plus the power requirements of the other devices supplied
via this circuit. The tripping characteristic of the higher-level fuse must hereby take into
consideration the starting currents of the IPC and those of the other devices.
SIMATIC IPC1047E
Operating Instructions, 03/2021, A5E50259546-AA
6BK1801-1XXXX-XXXX (for details, refer to the ordering documenta-
tion)
430 × 177 × 572 (W × H × D in mm). Detailed dimensional specifica-
tions can be found in section "Dimensional drawing of the device
(Page 111)".
Max. 25 kg
)
100 ... 240 V AC, (-10 %, +10 %), wide-range
N
Single power supply: Max. 13 A (100 V), max. 7 A (240 V)
Fuse, internal: 15 A, type "time-lag"
Redundant power supply: Max. 10 A (100 V), max. 5 A (240 V)
Fuse, internal: 12 A, type "time-lag"
Single power supply: Max. 30 A (115 V AC), max. 65 A (230 V AC)
Redundant power supply: Max. 80 A (115 V AC), max. 120 A (230 V AC)
50 to 60 Hz (min. 47 Hz to max. 63 Hz, sinusoidal)
AC power supply: Max. 860 W at 85% efficiency
Redundant AC power supply: Max. 700 W at 85% efficiency
< 48 dB(A) at 23°C IDLE
< 51 dB(A) at 23°C full load
according to DIN EN ISO 7779
IP 30
(front) with closed front door
1
IP 20
on the rear according to EN 60529
1
With closed front door
Filter class G2 EN 779, 99% of particles > 0.5 mm are filtered