Siemens SIMATIC IPC427E Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC427E:
Table of Contents

Advertisement

Quick Links

SIMATIC
Industrial PC
SIMATIC IPC427E
Operating Instructions
02/2021
A5E37454814-AE
Preface
Overview
Safety Instructions
Installing and connecting
the device
Commissioning the device
Extended device functions
Expanding and assigning
parameters to the device
Device maintenance and
repair
Technical specifications
Technical support
Markings and symbols
List of abbreviations
1
2
3
4
5
6
7
8
A
B
C

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC IPC427E

  • Page 1 Preface Overview SIMATIC Safety Instructions Installing and connecting the device Industrial PC SIMATIC IPC427E Commissioning the device Extended device functions Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications Technical support Markings and symbols...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Preface

    (Page 86)". Position in the information landscape The documentation for the IPC includes the following: • SIMATIC IPC427E Quick Install Guide with product information about the device, for example important notes • SIMATIC IPC427E Operating Instructions The documentation is supplied with the IPC in multiple languages in electronic form as a PDF file on the USB stick supplied in the documentation package.
  • Page 4 Preface Conventions The terms "PC" and "device" are sometimes used to refer to the SIMATIC IPC427E in this documentation. The term "Windows Embedded Standard" is used throughout to refer to "Windows Embedded Standard 7". "Windows 7" is used as an abbreviation for "Windows 7 Ultimate".
  • Page 5: Table Of Contents

    Connecting the device to networks ..................38 3.3.6 Installing the strain relief ....................39 3.3.7 Securing the lines ......................40 Commissioning the device ........................41 General information on commissioning ................41 Initial commissioning ......................42 Windows Action Center ...................... 43 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 6 Installing drivers and software ................... 74 7.4.4 Update installation ......................74 7.4.4.1 Updating the operating system ..................74 7.4.4.2 Installing or updating application programs and drivers ............75 7.4.5 Backing up data ......................... 75 Recycling and disposal ....................... 75 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 7 Battery status register (read-only, address 404Dh) ............104 8.6.4.6 NVRAM address register ....................105 BIOS description ......................106 8.7.1 Overview ......................... 106 8.7.2 Opening the BIOS selection menu ..................107 8.7.3 Structure of the BIOS Setup menu ..................108 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 8 Markings and symbols ........................117 Overview ......................... 117 Safety ..........................117 Operator controls ......................117 Certificates, approvals and markings ................118 Interfaces ........................119 List of abbreviations .......................... 120 Glossary ............................. 125 Index ..............................133 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 9: Overview

    Overview Product description The SIMATIC IPC427E provides high-level industrial functionality. • Compact design • Maintenance-free operation • High degree of ruggedness SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 10: Applications

    2 x DisplayPort, maximum resolution 4096 x 2304 pixels • Graphics memory is claimed in main memory (dynamic UMA) Power supply 24 V DC (-20%/+20%) max. 4 A Conditions of use Operation without fan Drives and storage media SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 11 Integrated Trusted Platform Module, optional, according to TPM 2.0 standard Software Operating systems Available • None • Windows Embedded Standard 7, SP1 • Windows 7 Ultimate, SP1 • Windows 10 IoT Enterprise LTSB 2016, 64-bit Project-specific • LINUX • • VxWorks SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 12: Design Of The Device

    ⑧ COM1 Serial interface (optional) ⑨ COM2 Serial interface (optional) 1.2.2 Status displays State Description PC ON/WD Green BIOS ready to boot; PC running Flashing green/yellow BIOS in POST, power switch on (1 Hz) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 13 Output register user LED L1/L2/L3 (read/write, address 404Eh) (Page 104). Example programs for controlling the LEDs on Windows operating systems are available on the Customer Support page of Siemens Industry Automation and Drive Technologies. (http://www.siemens.com/automation/service&support) SIMATIC IPC427E...
  • Page 14: Accessories

    Overview 1.3 Accessories Accessories Siemens offers accessories not included in the scope of delivery for the device. For more information on available accessories, refer to the Internet at: Industry Mall (https://mall.industry.siemens.com) Expansion components and accessories (http://www.automation.siemens.com/mcms/pc- based-automation/en/industrial-pc/expansion_components_accessories) SIMATIC IPC CFast cards •...
  • Page 15: Safety Instructions

    • Only install system expansion devices designed for this device. Contact your technical support team or where you purchased your PC to find out which system expansion devices may safely be installed. • Observe the information on electromagnetic compatibility (Page 78). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 16 Avoid high-frequency radiation: • Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Observe the information on electromagnetic compatibility (Page 78). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 17 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 18 Therefore, ensure there are adequate safeguards for protecting the administrator accounts to prevent unauthorized changes. To do this, use secure passwords and a standard user account for normal operation. Other measures, such as the use of security policies, should be applied as needed. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 19: Notes On Usage

    Use in an industrial environment without additional protective measures The device has been designed for use in a normal industrial environment in accordance with IEC 60721-3-3 (pollutant class 3C2 for chemical influences, 3S2 for dust without sand). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 20: Installing And Connecting The Device

    • Keep the original packaging. • Pack the device in the original packaging for transportation and storage. 5. Check the contents of the packaging and any accessories you may have ordered for completeness and damage. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 21 7. Please keep the enclosed documentation in a safe place. It belongs to the device. You need the documentation when you commission the device for the first time. 8. Write down the identification data of the device. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 22: Identification Data Of The Device

    Side surface of the device Only devices with preinstalled Windows operating systems Certificate of Authenticity (COA) have COA labels Ethernet address 1 BIOS setup, "Advanced" menu Ethernet address 2 Ethernet address 3 (optional) Rating plate SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 23 You usually do not need this product key for commissioning because a valid product key has already been integrated into the pre-installed operating system. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 24: Permitted Mounting Positions

    • When in doubt, install the device in an enclosure that meets the requirements of paragraph 9.3.2 of the IEC/UL/EN/DIN-EN 61010-2-201 standard. Horizontal mounting is the preferred position. The horizontal mounting options are as follows: Installation on a DIN rail The interfaces are at the bottom. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 25 The interfaces are the left. at the front. The power supply con- nection is at the top. Observe the permitted temperature range for operation in the respective mounting position as defined in "Technical specifications (Page 86)". SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 26: Installing The Device

    The device may not be securely fitted if you use anchors and screws other than those specified below for mounting. The device can fall and may be damaged. Use only the anchors and screws specified in the following table. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 27 8 mm, 40 mm deep • Dowel, ∅ 8 mm, 40 mm length • Screw, ∅ 5 mm, 40 mm length Plasterboard, 14 mm Toggle bolt, ∅ 4 mm, 50 mm length min. 13 mm thickness SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 28: Installation On A Din Rail

    The DIN rail is installed at the installation site. Note Ensure that the wall or ceiling can hold four times the total weight of the device including DIN profile rail and additional expansion cards. See Mounting instructions (Page 26). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 29: Wall Mounting

    Wall mounting The fasteners and screws required are supplied with the device for the selected mounting option (as specified in order number). Requirement • 2 mounting brackets • 6 screws • 1 T20 screwdriver SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 30: Upright Mounting

    The fasteners and screws required are supplied with the device for the selected mounting option (as specified in order number). Requirement • 2 mounting brackets • 6 screws • 1 T20 screwdriver Procedure 1. Secure each mounting bracket with three screws. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 31: Connecting The Device

    • Only connect I/O devices which are approved for industrial applications in accordance with EN 61000-6-2 and IEC 61000-6-2. • I/O devices that are not hotplug-capable may only be connected after the device has been disconnected from the power supply. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 32: Power Supply

    • Take a faulty device out of service immediately and mark it accordingly. Requirement • The device has been installed. • 1 protective conductor, minimum cross section 2.5 mm = AWG14 • 1 T20 screwdriver • 1 x M4 cable lug SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 33: Connecting The Power Supply

    If the device is installed in an enclosure that complies with section 9.3.2. c) of IEC/UL/EN 61010-1 and IEC/UL/EN 61010-2-201, it can be supplied from a source "higher than NEC Class 2 / Limited Energy". The device is then classified as "OPEN EQUIPMENT". SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 34: Connecting The Terminal

    (= AWG14). Only connect wires with a cross-section of ≥ 0.5 mm² (= AWG20). You can use either semi-rigid or flexible cables. You do not need to use end sleeves. Requirements • 1 connection terminal • 1 0.5 x 3 Philips screwdriver SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 35: Connecting Peripheral Equipment

    Only connect I/O devices that are suitable for industrial applications in accordance with EN IEC 61000-6-2. Note I/O devices capable of hot-plugging (USB) Hot-plug I/O devices (USB) may be connected while the PC is in operation. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 36: Connecting Expansion Cards

    Connecting expansion cards This section applies to devices with expansion cards. The expansion card interface is protected by a cover. There are two holes in the cover for wiring. Requirement • The device is switched off. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 37 3. Attach the cover at the points shown and close it. Make sure that the latching hooks snap into place so that the cover is secured. See also Dimension drawing - device with expansion cards (Page 85) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 38: Connecting The Device To Networks

    Note To use the Windows reboot with the SIMATIC CPU1507S (F) Software Controller on the SIMATIC IPC427E, assign the Ethernet interfaces X2 or X3 to the PC station in STEP 7. Industrial Ethernet You can establish a network between the device and other PCs via Industrial Ethernet. The on-board LAN interfaces are (Twisted-Pair) TP interfaces that support data transmission rates of 10/100/1000 Mbps.
  • Page 39: Installing The Strain Relief

    1. Removed the indicated countersunk screws and fasten the strain relief at the indicated points. Use the oval head screws included with the strain relief. Removal Follow the steps for installation in reverse order. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 40: Securing The Lines

    Cable tie width 3 mm max. • 1 cutting tool Procedure 1. Pass the cable tie around the strain relief bar and secure the cables as shown. 2. Cut off the protruding ends of the cable ties. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 41: Commissioning The Device

    • The protective conductor is connected. • The connection cables are plugged in correctly. • The following hardware is available for initial commissioning: – One USB keyboard – One USB mouse – A monitor/display SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 42: Initial Commissioning

    6. If the device is connected with a SIMATIC Industrial Flat Panel, the setup of the SIMATIC IPC Panel Drivers and Tools software is started automatically after operating system installation (see next section). The installation of the operating system is complete. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 43: Windows Action Center

    • Configuration via the IPC Configuration Center of: – Brightness – Screen saver – Tools – Touch settings – Ethernet Monitor settings All other functions are described in the IPC Panel Driver and Tools operating manual. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 44: Extended Device Functions

    The SIMATIC IPC DiagMonitor software can be ordered as an accessory (not included in the scope of delivery). The CD contains both the monitoring software and the software for the stations to be monitored. The interface specifications and a library for creating your own applications are also provided. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 45: Temperature Monitoring/Display

    Executes a hardware reset when the watchdog expires Reset off Executes no action when the watchdog expires Restart Restarts the operating system when the watchdog expires Shutdown Shuts down the operating system when the watchdog expires SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 46: Battery Monitoring

    When the first warning threshold is reached, the remaining service life of the battery for buffering time and CMOS data is at least 1 month. 5.1.5 Mass storage monitoring The state of HDD, SSD and CFast cards is monitored via SMART bit and reported by DiagBase or DiagMonitor. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 47: Unified Write Filter (Uwf)

    Proceed as follows to prevent this situation: • Make changes to storage media only when UWF is disabled. See also SIMATIC IPC Windows 10 User Manual (https://support.industry.siemens.com/cs/ww/de/view/109749498/en?dl=en) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 48: Enhanced Write Filter (Ewf)

    • "Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF Manager" Configure the SIMATIC IPC EWF Manager as follows: • "Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF Settings" • Click the "SIMATIC IPC EWF Manager" icon in the system tray.
  • Page 49 These changes are only retained on the PC in the following cases: • EWF is disabled when you make changes. • EWF is enabled and you save the changes before shutting down the device using the following command on C: drive : ewfmgr c: -commit SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 50 "Start > Control Panel > Date and Time", remove the check mark from the "Automatically adjust clock for daylight saving changes" check box. 2. Save the change you have made with ewfmgr c: -commit and then reboot the system. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 51: File Based Write Filter (Fbwf)

    • Observe the following syntax: Enter a space after the drive designation colon. • Changes for direct write access only take effect after rebooting. • Only existing files and folders can be entered in the exception list. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 52: Buffer Memory Nvram

    A USB keyboard and mouse and a monitor can be connected later for diagnostics. A digital DVI monitor or DisplayPort monitor cannot be activated retrospectively unless the Windows Embedded Standard or Windows 7 or Windows 10 Ultimate operating system has completed booting. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 53: Trusted Platform Modul (Tpm)

    The warranty does not cover a reset of the hardware in the event of a loss of a password. Please store the password carefully and make sure it is protected against unauthorized access. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 54: Expanding And Assigning Parameters To The Device

    ESD Directives on handling electrostatic-sensitive components in ESD guideline (Page 79). Requirement • The device is disconnected from the power supply. • 1 T10 screwdriver Procedure Opening the device 1. Remove the marked screws. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 55: Opening The Device Containing Expansion Cards

    You therefore need to take precautionary measures before you open the device. Please refer to the ESD Directives on handling electrostatic-sensitive components in ESD guideline (Page 79). Requirement • The device is disconnected from the power supply. • 1 T10 screwdriver SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 56: Replacing Memory Modules

    The motherboard is equipped with one slot for an SO-DIMM DDR4 memory module. You can use it to expand the memory capacity of the device to a maximum of 16 GB. Note Use only the memory modules recommended by Siemens AG. Requirement • The device is disconnected from the power supply.
  • Page 57 BIOS Setup menu under "Total Memory". After insertion and removal Close the device. The new memory capacity will be automatically detected and displayed in the BIOS setup when the device is switched on. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 58: Installing And Removing Cfast Cards

    If you are using the memory card in a device installed in a system, you must observe the safety regulations for work on electrical systems. Insert the CFast card into the slot, working carefully and without applying excess force. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 59 Push CFast card into the slot until it snaps into place. 3. Close and lock the cover. Removal Remove the CFast card from the memory slot by pushing it in until it is ejected by about 5 mm. Proceed in reverse order. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 60: Installing And Removing Pcie Cards

    Device version with one PCIe slot Figure 6-2 Device version with two PCIe slots Requirement • The device is disconnected from the power supply. • The device is open (see section "Opening the device containing expansion cards (Page 55)"). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 61 Configuring BIOS setup You may need to make settings in the BIOS Setup. For detailed information about installation, please refer to the documentation provided with the specific expansion card. See also Technical specifications (Page 86) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 62: Assigning Cpu Power Consumption Parameters

    Same as standard, but additionally optimized for deterministic operation with optimized constant CPU frequency. Temperature Setting for lowest power consumption. optimized The CPU clock is limited at a higher load. The maximum power consumption of the CPU is 12 W. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 63: Device Maintenance And Repair

    To maintain high system availability, we recommend that you replace PC components that are subject to wear, at the intervals for replacement indicated in the table below. Component Replacement interval Hard disk drive 3 years CMOS backup battery 4 years SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 64: Repair Information

    Make sure you take precautionary measures even when you open the device, for example, when opening device doors, device covers or the housing cover. For more information, refer to the section "ESD Guideline (Page 79)" SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 65 UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". We are not liable for functional limitations caused by the use of third-party devices or components. See also Spare parts and repairs (http://support.automation.siemens.com/WW/view/en/16611927) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 66: Installing And Removing Hardware

    This may damage the plant. Set the device time again. 1. Remove the indicated screws, pull the cover panel in direction of the arrow and lift it off. 2. Carefully remove the connector. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 67: Changing Storage Media

    Requirement • The device is disconnected from the power supply. • The device is removed. • 1 T10 screwdriver Procedure Note Observe the guidelines for handling electrostatic-sensitive components in section "ESD guideline (Page 79)". SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 68 4. Loosen the HDD/SSD on the side from the base plate as shown. The HDD/SSD is retained on the base plate by means of the studs shown. An addi- tional insulating film is inserted into the base plate for HDD operation. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 69 Take care that the nameplate is on top. Slide the HDD/SSD into the enclosure until you can see the mounting holes. 3. Turn in the marked screws. 4. Insert the cover into the enclosure. Turn in the marked screws. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 70: Installing The Software

    The supplied USB contains the installation program with tools for configuring the drives and installing the operating system with the supported languages. The basic language of the installed operating system is English. To add other languages, install these languages from the supplied USB stick ("Language packs" directory). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 71: Partitioning The Data Storage Medium

    13 GB 25 GB NTFS compressed Second DATA Remainder Remainder NTFS compressed * Due to partitioning/formatting, the actual CFast capacity does not correspond to the memory size specified on the SIMATIC IPC CFast card. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 72: Setting Up The Partitions Under Windows 7 Ultimate And Windows 10

    SSD/HDD: > 100 GB First Boot 260 MB FAT32 Second 128 MB None Third System 60 GB 100 GB NTFS, not compressed Fourth WinRE 500 MB NTFS, not compressed Fifth Data Remainder NTFS, not compressed SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 73: Adapting The Partitions Under Windows 7 Ultimate And Windows 10

    1. Click in the partition manager with the right mouse button on the partition to be increased and click on "Increase size". 2. Follow the instructions on the screen. Additional information is available in the "Help" menu under "Help topics" and "Search". SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 74: Installing Drivers And Software

    Note Before you install new drivers or operating system updates for Windows MUI versions, configure the regional menu and dialog settings and the default English (US) language. other operating systems Contact the corresponding manufacturer. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 75: Installing Or Updating Application Programs And Drivers

    (images). The SIMATIC IPC Image & Partition Creator can be ordered using the Siemens online ordering system (https://mall.industry.siemens.com). For more information about SIMATIC IPC Image & Partition Creator, refer to its product documentation.
  • Page 76: Technical Specifications

    Certificates and approvals ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001:2008. This has been certified by DQS (the German society for the certification of quality management systems).
  • Page 77 • ABS American Bureau of Shipping (USA) • BV Bureau Vertias (France) • DNV GL (Norway/Germany) • LR Lloyds Register of Shipping • Class NK Nippon Kaiji Kyokai (Japan) • China Classification Society (CCS) • Korean Certification (KC Mark) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 78: Declaration Of Conformity

    EN 61000-6-1 small businesses RoHs directive This product meets the requirements stated in the RoHS directive (Restriction of Hazardous Materials): 2011/65/EU Compliance with the directive has been reviewed according to the following standard: EN 50581 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 79: Directives And Declarations

    The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 80 There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 81 This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 82: Dimension Drawings

    Technical specifications 8.4 Dimension drawings Dimension drawings 8.4.1 Dimension drawing - mounting on a DIN rail SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 83: Dimension Drawing - Wall-Mounting

    Technical specifications 8.4 Dimension drawings 8.4.2 Dimension drawing - wall-mounting SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 84: Dimension Drawing - Vertical Mounting

    Technical specifications 8.4 Dimension drawings 8.4.3 Dimension drawing - vertical mounting SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 85: Dimension Drawing - Device With Expansion Cards

    Technical specifications 8.4 Dimension drawings 8.4.4 Dimension drawing - device with expansion cards Device with one expansion card Device with two expansion cards SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 86: Technical Specifications

    ± 1 kV to IEC 61000-4-4; Burst; Length < 3 m ± 2 kV in accordance with IEC 61000-4-4; Burst; length > 3 m ± 2 kV in accordance with IEC 61000-4-5; Surge; length > 30 m SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 87 • ≥ 30 GB Graphics Graphics controller Intel® HD Graphics 510 / 530 / P530 (depending on CPU type) Graphics memory Occupied in main memory (dynamic UMA) Graphics resolution Maximum 4096 x 2304 pixels SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 88: Ambient Conditions

    5 °C for the setting "Performance Optimized". - During storage/shipping -40°C to +60°C (for device with HDD) or -40°C to +70°C (for devices with CFast or SSD) - Gradient Operating mode: Max. 10°C/h; Storage: 20°C/h; no condensation SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 89: Power Demand Of The Components

    12 W for both slots Total The total power for PCIe cards and USB devices may not exceed 15 W NOTICE Device can overheat! To avoid overheating, the power loss per PCIe slot should not exceed 8 watts. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 90: Integrated Dc Power Supply

    SSD - additionally USB expansion - additionally Max. 500 mA Max. 12 W PCIe expansion - additionally Max. 500 mA Max. 12 W The total power for PCIe and USB expansions may not exceed 15 W SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 91: Restoring The Factory State

    4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Restore function and confirm the entry. 7. Follow the on-screen instructions. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 92: Windows 7 / Windows 10

    The BIOS selection menu is displayed when initialization is completed. 4. To boot from the USB stick, select the Boot Manager. 5. Select the USB stick in the Boot Manager and confirm the entry. 6. Select the Recovery function and confirm the entry. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 93: Setting Up Partitions Under Windows

    Changing the settings for language, region and formats of a registered user account 1. Choose: "Start > Control Panel > Clock, Language, and Region > Regional and Language Options" 2. You can make the desired changes in the "Formats", "Location" and "Keyboards and Languages" tabs. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 94 3. Click the "Install/uninstall languages" button and make the required changes. The following languages can be installed at a later time: Language Windows 7 / 10 German English French Italian Spanish Chinese (Hong Kong) Chinese (simplified) Chinese (Taiwan) Japanese Russian SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 95: Windows Embedded Standard

    Note the license terms of Windows Embedded Standard 7 Note the license terms for Windows Embedded Standard 7 and especially the extended software terms of the Siemens AG. You can find the license terms in the delivered document "MICROSOFT SOFTWARE LICENSE TERMS for Windows Embedded Standard 7"...
  • Page 96: Hardware Descriptions

    RS-232 assignment Short description Meaning Data carrier detect (I) Received data (I) Transmitted data (O) Data terminal ready (O) Ground Data set ready (I) Request to send (O) Clear to send (I) Incoming call (I) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 97: Cfast

    Signal GND (ground for signal integrity) Card Detect In Device GND TBD (not connected) TBD (not connected) TBD (not connected) TBD (not connected) Device GND LED1 LED Output (not connected) LED2 LED Output (not connected) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 98: Displayport

    Output Ground ML_Lane3- DP data 3- Output CONFIG1 CAD Cable Adapter Detect Input CONFIG2 Ground (PullDown) AUX_CH+ Auxiliary channel+ Bidirectional Ground AUX_CH- Auxiliary channel- Bidirectional Hot Plug Detect Input Ground DP_PWR +3.3V (fused) Output SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 99: Ethernet

    + 5 V (fused) Output Data channel USB2 Input / output Data channel USB2 Input / output Ground – Data channel USB3 Input Data channel USB3 Input Ground – Data channel USB3 Output Data channel USB3 Output SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 100: Internal Ports

    Lane 0 (not connected) Ground Ground PETp1 Transmitter differential pair, RSVD Reserved Lane 1 PETn1 Transmitter differential pair, Ground Lane 1 Ground PERp1 Receiver differential pair, Lane1 Ground PERn1 Receiver differential pair, Lane1 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 101: System Resources

    The interrupts are assigned to devices by BIOS. Only non-shared interrupts are available for the first Ethernet interface. This means that applications or realtime operating system expansions can operate these devices exclusively and with high-performance without having to share the interrupt with other devices. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 102: I/O Address Areas

    I/O 066h Watchdog trigger register (read only, address 066h) (Page 103) I/O 404Eh - 404Fh Output register LED 1/2/3 and SF LED / RUN/STOP LED (Page 104) I/O 404Dh Battery status register (read-only) (Page 104) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 103: Watchdog Enable Register / 066H Select Register (Read/Write, Address 062H)

    Watchdog trigger register (read only, address 066h) Watchdog trigger register The watchdog is triggered by a read action (address 066h) by this register. The result of the read access can be disregarded (i.e., dummy read). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 104: Output Register User Led L1/L2/L3 (Read/Write, Address 404Eh)

    Meaning of the bits Battery status register (read-only, address 404Dh) Meaning CMOS battery capacity is still sufficient. CMOS battery capacity is exhausted (remaining capacity is suffi- cient for approx. one month) CMOS battery is empty SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 105: Nvram Address Register

    NVRAM address register PCI register address: PCI register content: Length of the memory area NVRAM base address register NVRAM memory address (default) E300 0000 Address is assigned dynamically 80000 h (depending on device configura- tion) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 106: Bios Description

    Setup parameters may not be included, depending on your order. The interface of your BIOS Setup can deviate from the figures in this document. You can find a detailed description of the BIOS on the Support website under Entry ID 92189178 (http://support.automation.siemens.com/WW/view/en/92189178). SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 107: Opening The Bios Selection Menu

    BIOS Update Update BIOS from USB memory stick MEBx Start Intel Management Engine BIOS Extension from Active Management Technology Support (AMT) Supported by Windows 8 and higher See also General installation procedure (Page 70) SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 108: Structure Of The Bios Setup Menu

    Short help texts on the currently selected setup parame- ters are displayed in the center right-hand area. ⑤ Key assignment The key assignment for navigation in the BIOS Setup is found in the footer. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 109: Exit Menu

    • Save the BIOS Setup settings as user-specific profile. Save Custom Defaults The currently configured Setup parameters are saved as a custom profile (see also "Load Custom Defaults"). Discard Changes All changes are discarded. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 110: Bios Update

    BIOS update Check regularly if updates are available for download to your device. Additional information can be found on the Internet at the following address: After Sales Information System (http://www.siemens.com/asis). Noting down and restoring BIOS Setup settings NOTICE Irretrievable loss of data All BIOS Setup settings are deleted after the BIOS update.
  • Page 111: Alarm, Error And System Messages

    The CMOS clock was operated without battery or with a battery that was too weak, during battery change, for exam- ple. Check the CMOS clock. Keyboard controller error Keyboard defective or not connected no keyboard present SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 112: Functional Scope In Windows

    Available Remote Desktop Available Available SIMATIC IPC DiagBase Available Available Speech Available Not available System Management Administrative Tools Available Available Telnet Server Available Available User Account Control Available Available Windows Explorer Shell Available Available SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 113 Note the licensing agreements for Windows Embedded Standard 7. Additional information on language selection is available in the section "Setting up the language selection by means of the Multilanguage User Interface (MUI) (Page 93)". SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 114: Technical Support

    You can find additional information and support for the products described on the Internet at the following addresses: • Technical support (https://support.industry.siemens.com) • Support request form (http://www.siemens.com/automation/support-request) • After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) • SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) • Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
  • Page 115: Troubleshooting

    Install a suitable driver; the correct driver can often be downloaded does not have a suitable from the homepage of the device's manufacturer. driver for the USB device. The EWF for Windows Embedded Standard must first be disabled. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 116: Notes On The Use Of Third-Party Modules

    PC. If the error no longer occurs, the third- • Signal frequencies or signal party expansion card was the cause of the fault. Replace this levels are not adhered to expansion card with a Siemens card or contact the card sup- • Different connector pin as- plier. signments If the PC still crashes, contact your technical support team.
  • Page 117: Markings And Symbols

    Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 118: Certificates, Approvals And Markings

    CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Peri- Approved for Korea od) marking for China Test mark of the Underwriters Labora- Disposal information, observe the tories local regulations. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 119: Interfaces

    DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 120: List Of Abbreviations

    Term for the serial interface Communication Processor Communication computer Central Processing Unit Cathode Ray Tube Canadian Standards Association Canadian organization for tests and certifications according to own or binational standards (with UL / USA) standards SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 121 High Definition Audio Hard Disk Drive Hard disk drive Height unit Human Machine Interface User interface HORM Hibernate Once - Resume Many Hyper-Threading HTML Hyper Text Markup Language Script language for creating Internet pages. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 122 Interrupt the processor can not reject NTFS New Techniques File System Secure file system for Windows versions (2000, XP, 7) NVRAM Non Volatile Random Access Memory Non-volatile data memory. Data memory is re- tained without external power supply. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 123 Synonym for parallel port SRAM Static Random Access Memory Static RAM Solid State Drive SVGA Super Video Graphics Array Enhanced VGA standard with at least 256 colors Serial number of the device Software Total Cost of Ownership SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 124 Program monitoring with error detection and alarming. WLAN Wireless LAN Wireless local area network Wake on Local Area Network World Wide Web Execute Disable Capability Hardware implementation Extended Graphics Array Graphic standard, maximum resolution 1024x768 pixels. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 125: Glossary

    Cache High-speed access buffer for interim storage (buffering) of requested data. CE marking Communauté Européene The CE mark confirms compliance of the product with corresponding EC Directives, for example, with the EMC Directive. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 126 The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 127 10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 128 Intel Active Management Technology This technology permits the diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 129 Legacy Boot Device Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens provides the license keys for protected software. License key disk The license key disk contains the authorizations or license keys required to enable protected SIMATIC software.
  • Page 130 Recovery function of the USB stick Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 131 This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 132 Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 133: Index

    Power supply, 35 Protective conductor, 32 Connection elements, 12 Creating an image, 75 Factory state, 91 FAQs, 115 FBWF (File Based Write Filter), 51 FCC, 76 Data backup, 75 File Based Write Filter, 51 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 134 Protective measure Marine approval, 77 Static electricity, 81 Marking EU Declaration of Conformity, 78 Memory media Drives, 87 Radiation, 16 Memory modules, 87 High frequency radiation, 16 Monitoring functions, 44 Recovery function, 70 Motherboard, 87 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...
  • Page 135 Third-party expansion cards, 116 Trigger register Watchdog, 103 Troubleshooting/FAQs, 115 Unified Write Filter, 47 Update, 43 Updates Application programs and drives, 75 Operating system, 74, 74 USB 3.0 Interface, 99 User Account Control, 43 UWF, 47 SIMATIC IPC427E Operating Instructions, 02/2021, A5E37454814-AE...

Table of Contents