STM32L151x6/8/B, STM32L152x6/8/B
6.3.11
Electrical sensitivity characteristics
Based on three different tests (ESD, LU) using specific measurement methods, the device is
stressed in order to determine its performance in terms of electrical sensitivity.
Electrostatic discharge (ESD)
Electrostatic discharges (a positive then a negative pulse separated by 1 second) are
applied to the pins of each sample according to each pin combination. The sample size
depends on the number of supply pins in the device (3 parts × (n+1) supply pins). This test
conforms to the JESD22-A114/C101 standard.
Symbol
V
ESD(HBM)
V
ESD(CDM)
1. Based on characterization results, not tested in production.
Static latch-up
Two complementary static tests are required on six parts to assess the latch-up
performance:
•
A supply overvoltage is applied to each power supply pin
•
A current injection is applied to each input, output and configurable I/O pin
These tests are compliant with EIA/JESD 78A IC latch-up standard.
Symbol
LU
6.3.12
I/O current injection characteristics
As a general rule, current injection to the I/O pins, due to external voltage below V
above V
DD
However, in order to give an indication of the robustness of the microcontroller in cases
when abnormal injection accidentally happens, susceptibility tests are performed on a
sample basis during device characterization.
Table 39. ESD absolute maximum ratings
Ratings
Electrostatic discharge
voltage (human body model)
Electrostatic discharge
voltage (charge device
model)
Table 40. Electrical sensitivities
Parameter
Static latch-up class
(for standard pins) should be avoided during normal product operation.
DocID17659 Rev 10
Conditions
= +25 °C, conforming to
T
A
JESD22-A114
T
= +25 °C, conforming to
A
ANSI/ESD STM5.3.1
Conditions
= +105 °C conforming to JESD78A
T
A
Electrical characteristics
Maximum
Class
(1)
value
2
2000
II
500
Class
II level A
or
SS
79/129
Unit
V
103
Need help?
Do you have a question about the STM32L151CB and is the answer not in the manual?