5. STATE TRANSITION
(4) Bit definition of Status DO 2
Bit
Symbol
0
S_ZPAS
Z-phase already passed
0: Z-phase unpassed after start-up
1: Z-phase passed once or more after start-up
1
(Note)
2
3
S_ZSP
Zero speed state
S_ZSP turns on when the servo motor speed is at zero speed or less. Zero speed can be changed with [Pr.
PC07].
4
S_VLC
Limiting speed
When the speed reaches the speed limit value in the torque mode, S_VLC will turn on. When the servo is
off, TLC will be turned off.
The Status DO cannot be used in the position mode or velocity mode.
5
(Note)
6
S_IPF
During IPF
S_IPF turns on during an instantaneous power failure.
7
(Note)
8
S_PC
Under proportional control
S_PC turns on under proportional control.
9
(Note)
10
S_DB
External dynamic brake output
When the dynamic brake needs to operate, S_DB turns off.
11
(Note)
12
13
14
15
S_ZP2
Home position return completion 2
S_ZP turns off at servo-off. S_ZP2 is always on unless the home position is erased.
When a home position return completes normally, S_ZP2 turns on. S_ZP2 is always on unless the home
position is erased.
In the incremental system, it turns off with one of the following conditions.
1) [AL. 69 Command error] occurs.
2) Home position return is not being executed.
3) Home position return is in progress.
If a home position return completes once in the absolute position detection system, S_ZP2 is always on.
However, it will be off with one of the conditions 1) to 3) or the following.
4) The home position return is not performed after [AL. 25 Absolute position erased] or [AL. E3 Absolute
5) The home position return is not performed after the electronic gear ([Pr. PA06] or [Pr. PA07]) was
6) The home position return is not performed after the setting of [Pr. PA03 Absolute position detection
7) [Pr. PA14 Rotation direction selection/travel direction selection] was changed.
8) [Pr. PA01 Operation mode] was changed.
Note. The values in bit 1, 2, 5, 7, 9, and 11 to 14 at reading are undefined.
position counter warning] occurred.
changed.
system selection] was changed from "Disabled" to "Enabled".
Description