2. PROFINET NETWORK MODULE (ABCC-M40-PIR)
2. PROFINET NETWORK MODULE (ABCC-M40-PIR)
The PROFINET communication with an MR-J4-_TM_ servo amplifier requires the PROFINET network
module (ABCC-M40-PIR). The following shows the details.
2.1 Specifications
Category
Product name
Model
Manufacturer
External interface
Dimensions
Mass
2.2 Parts identification
This section describes the PROFINET network module (ABCC-M40-PIR) only. Refer to section 1.7 of "MR-
J4-_TM_ Servo Amplifier Instruction Manual" for the MR-J4-_TM_ servo amplifier.
(5)
(6)
ABCC-M40-PIR
AB6938-C
HMS Industrial Networks
MR-J4-_TM_ servo amplifier connecting interface: Compact flash connector with standard 50 pins
PROFINET communication port interface: RJ45 connector
52 (W) × 50 (D) × 20 (H)
Except the protrusion of the PROFINET communication port connector
Approx. 30 g
(3)
(1)
(2)
(4)
Description
No.
Name/Application
Module Status LED
(1)
Indicates the module status.
RJ45 PROFINET communication port (port 2)
(2)
Connect the controller or servo amplifier.
Link/Activity LED (port 2)
(3)
Indicates the link status of each PROFINET
communication port.
RJ45 PROFINET communication port (port 2)
(4)
Connect the controller or servo amplifier.
Link/Activity LED (port 1)
(5)
Indicates the link status of each PROFINET
communication port.
Network Status LED
(6)
Indicates the communication status.
2 - 1
Detailed
explanation
Section
2.2.2
Section 2.3
Section
2.2.3
Section 2.3
Section
2.2.3
Section
2.2.1