4.28

Transistor Outputs Selection Function

The transistor outputs selection function is the function that selects the internal transistor outputs function. Settings are made
for each channel separately.
The transistor output functions depend on the control mode settings as described below.
Transistor output
Control mode
functions
0 to 1: Standard PID
selection set
control
values
(Internal outputs)
0
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
1
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
2
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
3
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
4
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
5
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
6
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
7
OUT1
CH1 operations output
OUT2
CH2 operations output
OUT3
CH3 operations output
OUT4
CH4 operations output
*1 If control modes 4 or 5 are selected, use CH2 and CH4 control outputs or external outputs.
Setting method
Configure the settings as described below.
[Navigation window]  [Parameter]  Target module  [Module Parameter]  [Application Setting]  [Transistor
outputs function]
2 to 3: Standard PID
4 to 5: Heating/cooling
control
PID control
(External outputs)
(Internal outputs)
Normally OFF
CH1 heating operations output
Normally OFF
CH1 cooling operations output
Normally OFF
CH3 heating operations output
Normally OFF
CH3 cooling operations output
CH1 operations output
CH1 heating operations output
CH2 operations output
CH1 cooling operations output
CH3 operations output
CH3 heating operations output
CH4 operations output
CH3 cooling operations output
CH1 operations output
CH1 heating operations output
CH2 operations output
CH1 cooling operations output
CH3 operations output
CH3 heating operations output
CH4 operations output
CH3 cooling operations output
CH1 alert 1 status
CH1 heating operations output
CH2 alert 1 status
CH1 cooling operations output
CH3 alert 1 status
CH3 heating operations output
CH4 alert 1 status
CH3 cooling operations output
CH1 alert 2 status
CH1 heating operations output
CH2 alert 2 status
CH1 cooling operations output
CH3 alert 2 status
CH3 heating operations output
CH4 alert 2 status
CH3 cooling operations output
CH1 alert 3 status
CH1 heating operations output
CH2 alert 3 status
CH1 cooling operations output
CH3 alert 3 status
CH3 heating operations output
CH4 alert 3 status
CH3 cooling operations output
CH1 alert 4 status
CH1 heating operations output
CH2 alert 4 status
CH1 cooling operations output
CH3 alert 4 status
CH3 heating operations output
CH4 alert 4 status
CH3 cooling operations output
CH1 loop disconnection alert
CH1 heating operations output
status
CH2 loop disconnection alert
CH1 cooling operations output
status
CH3 loop disconnection alert
CH3 heating operations output
status
CH4 loop disconnection alert
CH3 cooling operations output
status
6 to 7: Heating/cooling
PID control
*1
(External outputs)
Normally OFF
Normally OFF
Normally OFF
Normally OFF
CH1 heating operations output
CH2 heating operations output
CH3 heating operations output
CH4 heating operations output
CH1 cooling operations output
CH2 cooling operations output
CH3 cooling operations output
CH4 cooling operations output
CH1 alert 1 status
CH2 alert 1 status
CH3 alert 1 status
CH4 alert 1 status
CH1 alert 2 status
CH2 alert 2 status
CH3 alert 2 status
CH4 alert 2 status
CH1 alert 3 status
CH2 alert 3 status
CH3 alert 3 status
CH4 alert 3 status
CH1 alert 4 status
CH2 alert 4 status
CH3 alert 4 status
CH4 alert 4 status
Normally OFF
Normally OFF
Normally OFF
Normally OFF