APPX
114
Appendix 4 Buffer Memory Areas
Setting detail
Standard PID
Heating/cooling
control
PID control
External output range lower limit
Transistor output functions selection
Startup tuning implementation command
Set value (SV) setting
Alert 1 set value
Alert 2 set value
Alert 3 set value
Alert 4 set value
Heater disconnection alert setting
AUTO/MAN mode
System area
switching
Manual output settings
System area
AT (auto tuning) implementation command
Operation mode setting
Proportional band (P)
Heating proportional
setting
band (P) setting
System area
Cooling proportional
band setting
Integral time (I) setting
Differential time (D) setting
Control response parameter
System area
Overlap/dead band
Upper limit output
Heating upper limit
limiter
output limiter
Lower limit output
System area
limiter
System area
Cooling upper limit
output limiter
Output change ratio
System area
limiter
Sensor correction value setting
Controller sensitivity (dead band) setting
Control output cycle
Heating control output
setting
cycle setting
System area
Cooling control output
cycle setting
Primary delay digital filter setting
Setting variation rate limiter
AT bias
Normal Operation/
System area
Reverse Operation
Setting
Monitor/Settings/
Default
Selection range
value
(Upper and lower limit reverse
0
operation disabled)
Page 161
0
0: Disabled
0
1: Enabled
Within setting limiter range
0
Depends on alert mode and
0
input type
Depends on alert mode and
0
input type
Depends on alert mode and
0
input type
Depends on alert mode and
0
input type
0 to 1000 (0.0 to 100.0 A) (0:
0
Heater disconnection
detection function OFF)
0: AUTO
0
1: MAN
-50 to +1050
-50/0
0: Stop AT
0
1: Implement AT
0: Not used
3
1: Monitor only
2: Monitor + alert
3: Monitor + alert + control
0 to 10000 (0.1 to 1000.0%
30
span)
Set 0 to use position 2
controls.
1 to 10000 (0.1 to 1000.0%
30
span)
0 to 3600 s
240
0 to 3600 s
60
0: Slow
0
1: Regular
2: Fast
-100 to +100
0
Lower limit output limiter +1 to
1000
1050/0 to 1050
-50 to upper limit output limiter
0
-1
0
0 to 1000
0
-5000 to +5000
0
0 to 100
10
5 to 1000 (0.5 to 100.0s)
300
5 to 1000 (0.5 to 100.0s)
0/300
0 to 100 s (0: Function OFF)
0
0 to 1000
0
±Input span [, , digit]
0
0: Normal Operation
1/0
1: Reverse Operation
Data type
Backup
Setting
Setting
Setting
Control
Control
Control
Control
Control
Control
Setting
Setting
Normal
Setting
Control
Control
Control
Control
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting
Setting