Temperature control
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Address:
CH
Setting detail
Decimal
Standard PID control
(hexadecimal)
633(279H)
CH2
Differential time (D) setting
634(27AH)
CH2
Alert set value 1
635(27BH)
CH2
Alert set value 2
636(27CH)
CH2
Alert set value 3
637(27DH)
CH2
Alert set value 4
638(27EH)
CH2
Temperature process value (PV) for input with another
(external) analog module
639(27FH)
CH2
System area
640 to 700
System area
(280H to 2BCH)
701(2BDH)
CH2
Input range
702, 703
System area
(2BEH, 2BFH)
704(2C0H)
CH2
Control output cycle setting
705(2C1H)
CH2
Control response parameter
706(2C2H)
CH2
Temperature rise completion range setting
707(2C3H)
CH2
Temperature rise completion soak time setting
708(2C4H)
CH2
Upper limit output limiter
709(2C5H)
CH2
Lower limit output limiter
710(2C6H)
CH2
Output change ratio limiter
711(2C7H)
CH2
Upper limit setting limiter
712(2C8H)
CH2
Lower limit setting limiter
713(2C9H)
CH2
Setting variation rate limiter
714(2CAH)
System area
715(2CBH)
CH2
Normal Operation/Reverse
Operation Setting
716(2CCH)
CH2
Adjustment sensitivity (dead band) setting
717(2CDH)
System area
718(2CEH)
CH2
AUTO/MAN mode shift
719(2CFH)
CH2
Manual output setting
720(2D0H)
System area
721(2D1H)
CH2
System area
722(2D2H)
CH2
System area
723(2D3H)
CH2
System area
724(2D4H)
CH2
System area
725 to 730
System area
(2D5H to 2DAH)
731(2DBH)
CH2
Alert dead band setting
732(2DCH)
CH2
Number of alert delay
733(2DDH)
CH2
Alert 1 mode setting
734(2DEH)
CH2
Alert 2 mode setting
735(2DFH)
CH2
Alert 3 mode setting
736(2E0H)
CH2
Alert 4 mode setting
737(2E1H)
CH2
Loop disconnection detection
judgment time
738(2E2H)
CH2
Loop disconnection detection
dead band
739 to 745
System area
(2E3H to 2E9H)
Heating/cooling PID
control
Cooling proportional band
(Pc) setting
Heating control output cycle
setting
Heating upper limit output
limiter
System area
System area
System area
System area
System area
Cooling upper limit output
limiter
Cooling control output cycle
setting
Cooling method setting
Overlap/dead band setting
*1
*1
*1
*1
System area
System area
Default value
Data type
60
Control
0
Control
0
Control
0
Control
0
Control
0
Control
30
Control
2
Setting
300
Setting
0
Setting
10
Setting
0
Setting
1000
Setting
0
Setting
0
Setting
1300
Setting
-100
Setting
0
Setting
1
Setting
10
Setting
0
Setting
-50
Setting
1000
Setting
300
Setting
0
Setting
0
Setting
10
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
480
Setting
0
Setting
Appendix 4 Buffer Memory Areas