CH1 External output range upper limit
Sets the upper limit of the external output values during external outputs.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
External output range upper limit
External output range upper limit (If using FX3 allocation mode)
■Setting range
The setting range is -32000 to +32000.
However, set so that external output range upper limit is greater than external output range lower limit.
■Default value
The default value is 10000.
CH1 External output range lower limit
Sets the lower limit of the external output values during external outputs.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
External output range lower limit
External output range lower limit (If using FX3 allocation mode)
■Setting range
The setting range is -32000 to +32000.
However, set so that external output range upper limit is greater than external output range lower limit.
■Default value
The default value is 0.
CH1 Transistor output functions selection
Sets the transistor output functions.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
External output range lower limit
External output range lower limit (If using FX3 allocation mode)
■Setting range
The setting range is 0 to 7.
For details, refer to Page 53 Transistor Outputs Selection Function.
■Enabling the settings
If changing the settings, turn OFF→ON→OFF the 'Settings change command' (Un\G399, b11) in normal mode to enable the
settings contents.
■Default value
The default value is 0.
CH1
CH2
595
795
84
124
CH1
CH2
596
796
85
125
CH1
CH2
597
797
86
126
Appendix 4 Buffer Memory Areas
CH3
CH4
995
1195
164
204
CH3
CH4
996
1196
165
205
CH3
CH4
997
1197
166
206
APPX
161
A

Advertisement

Table of Contents
loading

Table of Contents