Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 117

Temperature control
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Address:
CH
Setting detail
Decimal
Standard PID
(hexadecimal)
control
196(C4H)
CH4
Upper limit setting limiter
197(C5H)
CH4
Lower limit setting limiter
198(C6H)
CH4
Loop disconnection
detection judgment
time
199(C7H)
CH4
Loop disconnection
detection dead band
200(C8H)
CH4
Micro voltage input scaling upper limit
201(C9H)
CH4
Micro voltage input scaling lower limit
202(CAH)
CH4
External input range upper limit
203(CBH)
CH4
External input range lower limit
204(CCH)
CH4
External output range upper limit
205(CDH)
CH4
External output range lower limit
206(CEH)
CH4
Transistor output functions selection
207(CFH)
CH4
Startup tuning implementation command
208(D0H)
CH1
Input range
209(D1H)
CH1
Alert 1 mode setting
210(D2H)
CH1
Alert 2 mode setting
211(D3H)
CH1
Alert 3 mode setting
212(D4H)
CH1
Alert 4 mode setting
213(D5H)
CH1
System area
214(D6H)
CH2
Input range
215(D7H)
CH2
Alert 1 mode setting
216(D8H)
CH2
Alert 2 mode setting
217(D9H)
CH2
Alert 3 mode setting
218(DAH)
CH2
Alert 4 mode setting
219(DBH)
CH2
System area
220(DCH)
CH3
Input range
221(DDH)
CH3
Alert 1 mode setting
222(DEH)
CH3
Alert 2 mode setting
223(DFH)
CH3
Alert 3 mode setting
224(E0H)
CH3
Alert 4 mode setting
225(E1H)
CH3
System area
226(E2H)
CH4
Input range
227(E3H)
CH4
Alert 1 mode setting
228(E4H)
CH4
Alert 2 mode setting
229(E5H)
CH4
Alert 3 mode setting
230(E6H)
CH4
Alert 4 mode setting
231(E7H)
CH4
System area
232(E8H)
System area
233(E9H)
Alert dead band setting
234(EAH)
Number of alert delay
235(EBH)
Heater disconnection alert/Abnormal current
detection delay count setting during outputs OFF
Monitor/Settings/
Selection range
Heating/cooling
PID control
Lower limit setting limiter
value +1 to input range upper
limit
Input range lower limit to
Upper limit setting limiter
value -1
System area
0 to 7200 s
System area
0.0 or 0 to input span
-20000 to +20000
(Upper and lower limit reverse
operation disabled, 20000
max. using span)
-32000 to +32000
(Upper and lower limit reverse
operation disabled)
-32000 to +32000
(Upper and lower limit reverse
operation disabled)
Page 161
0: Disabled
1: Enabled
Page 140
0 to 14
0 to 14
0 to 14
0 to 14
Page 140
0 to 14
0 to 14
0 to 14
0 to 14
Page 140
0 to 14
0 to 14
0 to 14
0 to 14
Page 140
0 to 14
0 to 14
0 to 14
0 to 14
Cooling method setting
0: Air cooling
1: Water cooling
2: Cooling gain linear
0 to 100
0 to 30000 times
3 to 255 times
Default
Data type
Backup
value
1300
Setting
-100
Setting
480/0
Setting
0
Setting
10000
Setting
0
Setting
10000
Setting
0
Setting
10000
Setting
0
Setting
0
Setting
0
Setting
2
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
2
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
2
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
2
Setting
0
Setting
0
Setting
0
Setting
0
Setting
0
Setting
10
Setting
0
Setting
3
Setting
APPX
Appendix 4 Buffer Memory Areas