Mitsubishi Electric MELSEC iQ-F FX5 User Manual page 121

Temperature control
Hide thumbs Also See for MELSEC iQ-F FX5:
Table of Contents

Advertisement

Automatic setting monitor at input range change
The value set in 'Automatic setting at input range change' (Un\G302) is stored.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
Automatic setting monitor at input range change
Control mode selection
Select the control mode for each control group. The control groups are divided into control group 1 (channels 1 and 2) and
control group 2 (channels 3 and 4), and share common settings within their group.
Normal mode
Set using bits 1 to 3 for each group.
GR2
Bit
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
(1)
(1) Set value
Control mode
000
0
001
1
010
2
011
3
100
4
101
5
110
6
111
7
• If the inputs are "internal", implement control using the process values detected by the internal inputs of the temperature
control module.
• If the inputs are "external", implement control using the value stored in 'CH1 Temperature process value (PV) for input with
another (external) analog module' (Un\G438). Temperature control module internal inputs are not used.
• If the outputs are "internal", implement control using the internal transistor outputs of the temperature control module.
• If the outputs are "external", implement control using the values stored in 'CH1 Manipulated value (MV) for output with
another (external) analog module'/'CH1 Manipulated value for heating (MVh) for output with another (external) analog
module' (Un\G407) and 'CH1 Manipulated value for cooling (MVc) for output with another (external) analog module'
(Un\G409).
• To enable the settings changes in normal mode, it is necessary to write the set values to buffer memory, and
then to turn OFF→ON→OFF again the settings change command (Un\G399, b11).
• Control mode cannot be changed while implementing controls. If changed, the changes will be reflected
when control stops.
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
Control mode selection
Control mode selection (If using FX3 allocation mode)
■Default value
Set to standard PID control (0).
CH1
39
FX3 allocation mode
Set using bits 1 to 3.
GR1
Bit
(1)
Control types
Standard PID control
Standard PID control
Standard PID control
Standard PID control
Heating/cooling PID control
Heating/cooling PID control
Heating/cooling PID control
Heating/cooling PID control
CH1
GR1
300
240
CH2
CH3
15
14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Input
Internal
External
Internal
External
Internal
External
Internal
External
CH2
CH3
GR2
241
Appendix 4 Buffer Memory Areas
CH4
(1)
Output
Internal
Internal
External
External
Internal
Internal
External
External
CH4
APPX
119
A