Electrical Connections; Process Connections; Rosemount 2051C Process Wetted Parts; Rosemount 2051T Process Wetted Parts - Emerson Rosemount 2051 Reference Manual

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Specifications and Reference Data
November 2016

A.3.2 Electrical connections

1
/
–14 NPT, G
1
/
, and M20
2
2
A.3.3 Process connections
Rosemount 2051C
1
/
–18 NPT on 2
1
/
-in. centers
4
8
1
/
–14 NPT and RC
1
/
on 2-in.(50,8 mm), 2
2
2
mm), or 2
1
/
-in. (57,2 mm) centers (process adapters)
4
Rosemount 2051T
1
/
–14 NPT female
2
G
1
/
A DIN 16288 male
2
(available in SST for Range 1–4 transmitters only)
Autoclave type F-250-C (pressure relieved
thread;
1
/
O.D. high pressure tube 60° cone; available in
4
SST for Range 5 transmitters only)
Rosemount 2051L
High pressure side: 2-in.(50,8 mm), 3-in. (72 mm), or
4-in. (102 mm), ASME B 16.5 (ANSI) Class 150 or 300
flange;
50, 80, or 100 mm, DIN 2501 PN 40 or 10/16 flange
Low pressure side:
1
/
–18 NPT on flange,
4
process adapter
Rosemount 2051CF
For Rosemount 2051CFA wetted parts, see Rosemount
DP Flowmeters and Primary Elements
Sheet
in the 485 section
For Rosemount 2051CFC wetted parts, see Rosemount
DP Flowmeters and Primary Elements
Sheet
in the 405 section
For Rosemount 2051CFP wetted parts, see Rosemount
DP Flowmeters and Primary Elements
Sheet
in the 1195 section
A.3.4 Rosemount 2051C process wetted
parts
Drain/vent valves
316 SST or Alloy C-276
Process flanges and adapters
Plated carbon steel, SST CF-8M (cast version of 316 SST,
material per ASTM-A743), or CW2M (cast version of Alloy C)
Wetted O-rings
Glass-filled PTFE or graphite-filled PTFE
70
1.5 conduit
1
/
-in. (54,0
8
9
/
–18 gland
16
1
/
–14 NPT on
2
Product Data
Product Data
Product Data
Process isolating diaphragms
316L SST, Alloy C-276, or Tantalum
A.3.5 Rosemount 2051T process wetted parts

Process connections

316L SST or Alloy C-276
Process Isolating diaphragms
316L SST or Alloy C-276
A.3.6 Rosemount 2051L Process wetted parts
Flanged process connection (transmitter high side)
Process diaphragms, including process gasket
surface
316L SST, Alloy C-276, or Tantalum
Extension
CF-3M (Cast version of 316L SST, material per
ASTM-A743), or Cast C-276. Fits schedule 40 and 80
pipe.
Mounting flange
Zinc-cobalt plated CS or SST
Reference process connection (transmitter low side)
Isolating diaphragms
316L SST or Alloy C-276
Reference flange and adapter
CF-8M (cast version of 316 SST, material per
ASTM-A743)
A.3.7 Non-wetted parts for Rosemount
2051C/T/L
Electronics housing
Low-copper aluminum or CF-8M (cast version of 316 SST).
Enclosure type 4X, IP 65, IP 66, IP68
Housing material code P: PBT/PC with NEMA 4X and
IP66/67/68
Paint for aluminum housing
Polyurethane
Coplanar sensor module housing
CF-3M (cast version of 316L SST)
Bolts
ASTM A449, Type 1 (zinc-cobalt plated carbon steel)
ASTM F593G, Condition CW1 (Austenitic 316 SST)
ASTM A193, Grade B7M (zinc plated alloy steel)
Alloy K-500
Reference Manual
00809-0300-4101, Rev BB
Specifications and Reference Data

Hide quick links:

Advertisement

Table of Contents
loading