Emerson Rosemount 2051 Reference Manual page 106

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Specifications and Reference Data
November 2016
Table A-15. Rosemount 2051T In-line Pressure Transmitter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
QG
Calibration certificate and GOST verification certificate
QP
Calibration certificate and tamper evident seal
Material traceability certification
Q8
Material traceability certification per EN 10204 3.1
Quality certification for safety
QS
Prior-use certificate of FMEDA data
QT
Safety certified to IEC 61508 with certificate of FMEDA
Surface finish
Q16
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZ
Remote seal system performance calculation report
Conduit electrical connector
GE
M12, 4-pin, male connector (eurofast)
GM
A size mini, 4-pin, male connector (minifast)
(24)
NACE certificate
Q15
Certificate of compliance to NACE MR0175/ISO 15156 for wetted materials
Q25
Certificate of compliance to NACE MR0103 for wetted materials
Typical model number: 2051T G 3 A 2B 2 1 A B4 M5
1.
Wireless output (code X) only available in absolute measurement type (code A) in range 1–5 with
housing code (c ode P).
2.
HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To
order HART Revision 7 factory configured, add option code HR7.
3.
Wireless output (code X) only available in G
2), silicone fill fluid (code 1), and housing code (code P).
4.
Not available with output code X.
5.
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental
limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Order with Q15 or Q25 to receive a NACE certificate.
6.
Not available with low power output code M.
7.
Only available with output code X.
8.
Transmitter conduit entry will be
9.
Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
10. Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
11. "Assemble-to" items are specified separately and require a completed model number.
12. Only valid with F
OUNDATION
13. Not available with coned and threaded connection (2F code), assemble-to manifold (S5 code), assemble-to seal (S1 code), surface finish certification
(Q16 code), remote seal system report (QZ code).
14. Not available with F
OUNDATION
15. Only Available with HART (output codes A and M).
16. Only available with HART 4–20 mA output (output code A) and wireless output (output code X).
17. Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
18. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
96
(22)
(4)
1
/
A DIN 16288 Male process connection (code 2C) with range 1–4, 316 SST isolating diaphragm (code
2
1
1
1
/
NPT and a
/
NPT to G
/
2
2
2
Fieldbus output code F.
Fieldbus output code F or wireless output code X.
thread adapter will be provided.
Reference Manual
00809-0300-4101, Rev BB
1
/
–14 NPT process connection (code 2B), and
2
Specifications and Reference Data

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents