00809-0300-4101, Rev BB
7.
Transmitter conduit entry will be
8.
Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
9.
Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
10. Requires 0 code in Materials of Construction for alternate process connection.
11. Not valid with optional code P9 for 4500 psi static pressure.
12. "Assemble-to" items are specified separately and require a completed model number.
13. Process flange limited to coplanar (codes 2, 3, 5, 7, 8) or traditional (H2, H3, H7).
14. Not valid with optional code D9 for RC
15. Not valid with optional codes DF or D9 for adapters.
16. Only valid with F
Fieldbus output code F.
OUNDATION
17. Not available with Alloy C-276 isolator (3 code), tantalum isolator (5 code), all cast C-276 flanges, all plated CS flanges, all DIN flanges, all Level flanges,
assemble-to manifolds (S5 and S6 codes), assemble-to seals (S1 and S2 codes), assemble-to primary elements (S3 and S4 codes), surface finish
certification (Q16 code), and remote seal system report (QZ code).
18. Not available with F
OUNDATION
19. Only Available with HART 4–20 mA (output codes A and M).
20. Only available with HART 4–20 mA output(output codes A) and wireless output (output code X).
21. Not valid with alternate process connection options S3, S4, S5, S6.
22. Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
23. Not available with alternate process connection: DIN flanges and Level flanges.
24. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
25. Available with 4–20 mA HART output code A, wireless output code X, F
Rosemount 2051T Ranges 1–4, SST and Alloy C 276 diaphragms and silicone fill fluid. High performance option includes 0.05% reference accuracy,
and five year stability. See
"Performance specifications" on page 61
26. The T1 option is not needed with FISCO Product Certifications; transient protection is included in the FISCO product certification codes IA and IE.
27. NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
28. Only available with HART 4–20 mA output (output code A).
29. NACE-Compliant wetted materials are identified by
Specifications and Reference Data
1
1
1
/
NPT and a
/
NPT to G
/
thread adapter will be provided.
2
2
2
1
/
adapters.
2
Fieldbus output code F or wireless output code X.
Footnote 2.
Specifications and Reference Data
Fieldbus output code F, Rosemount 2051C Ranges 2–5 or
OUNDATION
for details.
November 2016