Emerson Rosemount 2051 Reference Manual page 119

Pressure transmitter with profibus pa protocol
Hide thumbs Also See for Rosemount 2051:
Table of Contents

Advertisement

Reference Manual
00809-0300-4101, Rev BB
Table A-17. Rosemount 2051CFC Compact Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Sensor fill fluid and O-ring options
(14)
L1
Inert sensor fill fluid
L2
Graphite-filled (PTFE) O-ring
(14)
LA
Inert sensor fill fluid and graphite-filled (PTFE) O-ring
Display and interface options
(11)
M
LCD display with local operator interface
M5
LCD display
(7)(14)(15)
Transient protection
T1
Transient terminal block
Manifold for remote mount option
F2
3-valve manifold, stainless steel
F6
5-valve manifold, stainless steel
(7)(16)
Alarm limit
(17)
C4
NAMUR alarm and saturation levels, high alarm
(17)
CN
NAMUR alarm and saturation levels, low alarm
CR
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
CS
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
CT
Low alarm (standard Rosemount alarm and saturation levels)
PlantWeb control functionality
A01
F
OUNDATION
Hardware adjustments
(16)
D4
Zero and span hardware adjustments
(18)
DZ
Digital zero trim
(7)(14)(19)
Ground screw
V5
External ground screw assembly
HART revision configuration
(20)
HR5
Configured for HART Revision 5
(21)
HR7
Configured for HART Revision 7
Typical model number: 2051CFC D C S 060 N 065 0 3 2 A A 1 WC E5 M5
1.
Not available for Primary Element Technology C.
2.
For the 10-in. (250 mm) and 12-in. (300 mm) line size, the alignment ring must be ordered (installation accessories).
3.
10-in. (250 mm) and 12-in. (300 mm) line sizes not available with Primary Element Technology A.
4.
For 2-in. (50 mm) line sizes the Primary Element type is 0.6 for Primary Element Technology code C.
5.
Available with Primary Element Technology A only.
Specifications and Reference Data
(7)
(7)
(7)
(7)(13)
Fieldbus advanced control function block suite
(7)
(7)(16)
Specifications and Reference Data
November 2016
109

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents