Specifications and Reference Data
November 2016
A.5 Dimensional drawings
Figure A-1. Rosemount 2051C Exploded View
C
B
A
P
O
N
A. Cover
B. Cover O-ring
C. Terminal block
D. Electronics housing
E. Local configuration buttons
F. Nameplate
G. Electronics board
H. Housing rotation set screw (180° maximum housing
rotation without further disassembly)
1.
Span and zero adjustment buttons are optional with 4–20 mA and 1–5 Vdc HART protocol. Local operator interface buttons are optional for PROFIBUS
PA Protocol. Local configuration buttons are not available with F
74
F
E
D
(1)
G
H
I
J
K
L
M
I. Sensor module
J. Process O-ring
K. Flange adapter O-ring
L. Flange alignment screw (not pressure retaining)
M. Flange bolts
N. Flange adapters
O. Drain/vent valve
P. Coplanar flange
Fieldbus.
OUNDATION
Reference Manual
00809-0300-4101, Rev BB
Specifications and Reference Data