Specifications and Reference Data
November 2016
Table A-18. Rosemount 2051CFP Integral Orifice Flowmeter Ordering Information
★ The Standard offering represents the most common options. The starred options (★) should be selected for best delivery.
The Expanded offering is subject to additional delivery lead time.
Hardware adjustments
(15)
D4
Zero and span hardware adjustments
(17)
DZ
Digital zero trim
(3)(13)(18)
Ground screw
V5
External ground screw assembly
HART revision configuration
(19)
HR5
Configured for HART Revision 5
(20)
HR7
Configured for HART Revision 7
Typical model number: 2051CFP D S 010 W1 S 0500 D3 2 A A 1 E5 M5
1.
To improve pipe perpendicularity for gasket sealing, socket diameter is smaller than standard pipe O.D.
2.
HART Revision 5 is the default HART output. The Rosemount 2051 with Selectable HART can be factory or field configured to HART Revision 7. To
order HART Revision 7 factory configured, add option code HR7.
3.
Not available with low power output code M.
4.
Only available with output code X.
5.
Transmitter conduit entry will be
6.
Thermowell Material is the same as the body material.
7.
Does not apply to process connection codes T1 and S1.
8.
Not available for bore sizes 0010, 0014, 0020, or 0034.
9.
Not available with DIN process connection codes D1, D2, or D3.
10. Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments.
Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour
refining environments.
11. Not available with F
OUNDATION
12. Only valid with F
OUNDATION
13. Not available with output code X.
14. Not available with housing code 00, 5A, or 7J. The T1 option is not needed with FISCO Product Certifications, transient protection is included with the
FISCO Product Certification code IA.
15. Only available with 4–20 mA HART (output codes A and M).
16. NAMUR-Compliant operation is pre-set at the factory and cannot be changed to standard operation in the field.
17. Only available with HART 4–20 mA (output codes A and M) and wireless (output code X).
18. The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
19. Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
20. Configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 if needed.
116
(3)
(3)(15)
1
1
1
/
NPT and a
/
NPT to G
/
2
2
2
Fieldbus (Output Code F) or Wireless (Output Code X).
Fieldbus output code F.
thread adapter will be provided.
Reference Manual
00809-0300-4101, Rev BB
Specifications and Reference Data