Connection to the control
5.2 Assigning the connection parameters
5.2
Assigning the connection parameters
5.2.1
Enable control ports
5.2.1.1
Overview
You must access port 22 to establish a connection from AMM to the control. You must access
port 5900 to establish a connection from AMM via remote control.
Three ways of enabling a port are described below for each port access required.
● Enabling ports from the HMI (Page 22)
● Otherwise: Enable ports via basesys.ini (Page 24)
● Otherwise: Enabling ports via the service shell (Page 25)
Note
Ports on the SINUMERIK 808D and 828D controls can only be enabled from the user interface.
5.2.1.2
Enabling ports from the HMI
Operating sequence for 840D sl/828D controls
1. Open the "Commissioning > Network" menu on your control.
2. Open extended horizontal softkeys with the right arrow key.
3. Open the "Workplace network" menu on your control.
4. The "Workplace network settings" window opens.
22
SINUMERIK Integrate Access MyMachine /P2P (PC)
Operating Manual, 11/2016, A5E39356962B AA