MOTO GUZZI B043157 Service Station Manual page 115

Table of Contents

Advertisement

Moto Guzzi California 1400
Continue fault search for the other errors detected.
CAUTION
DELETING ALL THE SAVED DATA WHEN THE VEHICLE IS BEING MANUFACTURED (INCLUD-
ING THE SELF-ADJUSTABLE PARAMETERS), THEN YOU MUST SELECT: HANDLE SELF-
LEARNING AND VERIFY THAT THE TWO "THROTTLE VALVE AUTOMATIC SELF-LEARNING"
STATUS IS "CARRIED OUT".
See also
Cylinders synchronisation
Saved data file download
Error cause
The BUFRSVXX.BIN file is saved in the diagnostics instrument memory card or in your hard
disk PC, if you are using Piaggio Software: data regarding the control unit serial number and
the serial number of the diagnosis instrument that has carried out the download is also
included in the file
Saved data file deletion
Error cause
Deletion enabled only if the file is downloaded after setting KEY ON
NEW CONTROL UNIT ACTIVATION PROCEDURE and REPROGRAMMING
After installing the control unit for the first time, or after REPROGRAMMING the control unit with a
different or more updated mapping, turn the key to ON and wait 3 seconds; during this time the control
unit carries out throttle position acquisition. Connect to the diagnostics instrument and check that the
status for "Throttle self-learning" is "Carried out" and the status for "Handle self-learning" is "Not carried
out" (the latter status entails Urgent service being displayed on the instrument panel). If Throttle Self-
learning shows "Not carried out", go to stage 1. If it shows "Carried out", go to stage 2. Phase 1: current
errors have probably been detected by the control unit: solve these malfunctions and check the two
statuses. Throttle Self-learning can also be checked from the Parameter adjustment (screwdriver and
hammer) screen page. Stage 2: Carry out the Handle Self-learning from the Parameter adjustment
(screwdriver and hammer) screen page and check that Handle Self-learning status is Carried out. If not
OK the voltage detected on the throttle is out of scale (check with diagnosis instrument) or current errors
have been probably detected by the control unit: solve these malfunctions and repeat the procedure
Electrical system
ELE SYS - 115

Advertisement

Table of Contents
loading