Electrical System Technical Data; Ignition Timing Control System - Yamaha F200B Service Manual

Hide thumbs Also See for F200B:
Table of Contents

Advertisement

SPEC

Electrical system technical data

Ignition timing control system

Item
Spark plug
Gap
Ignition coil
Input voltage
Pulser coil
Air gap
Resistance (*1)
At 20 °C (68 °F)
Output peak voltage
At cranking (unloaded)
At cranking (loaded)
At 1500 r/min (loaded)
At 3500 r/min (loaded)
Cam position sensor
Input voltage
Knock sensor
Resistance (*1)
At 20 °C (68 °F)
Air temperature sensor
Resistance (*1)
At 20 °C (68 °F)
At 80 °C (176 °F)
Input voltage
Neutral switch
Input voltage
Air pressure sensor
Input voltage
Output voltage
At –20.0 kPa (–0.20
2
kgf/cm
, –2.9 psi)
At –46.7 kPa (–0.467
2
kgf/cm
, –6.8 psi)
Engine temperature sensor
Resistance (*1)
At 20 °C (68 °F)
At 100 °C (212 °F)
Thermoswitch
Input voltage (*1)
Temperature
Switch ON
Switch OFF
(*1) The figures are for reference only.
1-7
Specification
Unit
mm (in)
V
mm (in)
V
V
V
V
V
kΩ
kΩ
kΩ
V
V
V
V
V
kΩ
kΩ
V
°C (°F)
°C (°F)
Model
F200BET FL200BET F250GET FL250GET
1.0–1.1 (0.039–0.043)
1.4–1.6 (0.055–0.063)
396.0–594.0
504.0–616.0
2.21–2.69
4.75–5.25
4.75–5.25
4.75–5.25
54.2–69.0
3.12–3.48
84–90 (183–194)
68–82 (154–180)
12.0
3.0
2.7
14.5
17.8
12.0
0.32
3.21
2.16
11.4