Checking The Connecting Rod Small End Inside Diameter And Big End Inside Diameter; Checking The Connecting Rod Big End Side Clearance; Checking The Crankshaft - Yamaha F200B Service Manual

Hide thumbs Also See for F200B:
Table of Contents

Advertisement

a
Piston pin outside diameter a:
21.008–21.017 mm (0.8271–0.8274
in)
Checking the connecting rod small
end inside diameter and big end
inside diameter
1. Tighten the connecting rod bolts 1 to the
specified torques in 3 stages.
2. Measure the connecting rod small end
inside diameter a and big end inside
diameter b.
90
d
b
1
Connecting rod bolt 1:
1st: 13 N·m (1.3 kgf·m, 9.6 ft·lb)
2nd: 23 N·m (2.3 kgf·m, 17.0 ft·lb)
3rd: 90°
Connecting rod small end inside
diameter a:
21.022–21.037 mm (0.8276–0.8282
in)
Connecting rod big end inside diameter b:
53.015–53.035 mm (2.0872–2.0880
in)
TIP:
• When checking the big end inside diame-
ter, reuse the removed connecting rod bolt.
• Make sure that the protrusions c on the
connecting rod and connecting rod cap are
aligned.
• In the 3rd tightening stage for the connect-
ing rod bolts 1, mark the connecting rod
bolts and the connecting rod cap with iden-
tification marks d, and then tighten the
bolts 90° from the marks on the connecting
rod cap.
Checking the connecting rod big end
side clearance
1. Measure the connecting rod big end side
a
c
Connecting rod big end side clearance a:

Checking the crankshaft

1. Measure the crankshaft journal diame-
clearance a.
a
0.150–0.300 mm (0.0059–0.0118 in)
ters a, crankpin diameters b, and
crankpin widths c.
a
Cylinder block
7
7-88