Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
13.6 SET BASIC ROTATION (Cycle 404, DIN/ISO: G404)
13.6
SET BASIC ROTATION (Cycle 404,
DIN/ISO: G404, software option 17)

Cycle run

With Touch Probe Cycle 404, during program run you can
automatically set any basic rotation or save it to the preset table. You
can also use Cycle 404 if you want to reset an active basic rotation.

Cycle parameters

Preset value for rotation angle: Angular value at
which the basic rotation is to be set. Input range
-360.000 to 360.000
Preset number in table Q305: Enter the preset
number in the table in which the TNC is to save
the determined basic rotation. Input range -1 to
99999. If you enter Q305=0 or Q305=1, the TNC
additionally saves the determined basic rotation
in the basic rotation menu (PROBING ROT) of the
Manual Operation mode.
-1
0
the basic rotation to preset line 0 and activate
preset 0
>1
preset. The preset is not activated.
322
= Overwrite and activate the active preset
= Copy the active preset to preset line 0, write
= Save the basic rotation to the specified
NC blocks
5 TCH PROBE 404 BASIC ROTATION
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 9/2015
Q307=+0
;PRESET ROTATION
ANG.
Q305=-1
;NO. IN TABLE