15
Touch Probe Cycles: Automatic Workpiece Inspection
15.10 MEASURE RIDGE WIDTH (Cycle 426, DIN/ISO: G426)
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (see "Tool
monitoring", page 388). Input range 0 to 32767 .9,
alternatively tool name with up to 16 characters
0: Monitoring inactive
>
414
0: Tool number in the tool table TOOL.T
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 9/2015