Maximum limit of size Q288: Maximum
permissible measured value. Input range 0 to
99999.9999
Minimum limit of size Q289: Minimum permissible
measured value. Input range 0 to 99999.9999
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (see "Tool
monitoring", page 388). Input range 0 to 32767 .9,
alternatively tool name with up to 16 characters
0: Monitoring inactive
>
0: Tool number in the tool table TOOL.T
The parameters
on this cycle. You do not need to make any entries.
These parameters have only been integrated for
reasons of compatibility. If, for example, you import
a program of the contouring control for turning
and milling, TNC 640, you will not receive an error
message.
HEIDENHAIN | TNC 620 | User's manual for cycle programming | 9/2015
MEASURE COORDINATE (Cycle 427, DIN/ISO: G427) 15.11
Q498
and
Q531
have no impact
Q309=0
;PGM STOP IF ERROR
Q330=0
;TOOL
Q498=0
;REVERSE TOOL
Q531=0
;INCLINED ANGLE