13
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
13.6 SET BASIC ROTATION (Cycle 404, DIN/ISO: G404)
13.6
SET BASIC ROTATION (Cycle 404,
DIN/ISO: G404)
Cycle run
With Touch Probe Cycle 404, during program run you can
automatically set any basic rotation or save it to the preset table. You
can also use Cycle 404 if you want to reset an active basic rotation.
Cycle parameters
Q307 Preset value for rotation angle: Angular
value at which the basic rotation is to be set. Input
range -360.000 to 360.000
Q305 Preset number in table?: Enter the preset
number in the table in which the TNC is to save
the determined basic rotation. Input range -1 to
99999. If you enter Q305=0 or Q305=1, the TNC
additionally places the determined basic rotation
in the basic rotation menu (PROBING ROT) of the
Manual Operation mode.
-1
0
the basic rotation to preset line 0 and activate
preset 0
>1
preset. The preset is not activated
318
= Overwrite and activate the active preset
= Copy the active preset to preset line 0, write
= Save the basic rotation to the specified
NC blocks
5 TCH PROBE 404 SET BASIC ROTATION
HEIDENHAIN | TNC 320 | User's manual for cycle programming | 9/2016
Q307=+0
;PRESET ROTATION
ANG.
Q305=-1
;NUMBER IN TABLE