Ricoh MD-P2 Field Service Manual page 257

Table of Contents

Advertisement

1102
[S-to-S Reg.] Side-to-Side Registration
These SPs can be adjusted by UP mode. The setting range of SP1102 is different from the
setting range of SP1002.
001 By-pass 0.34mm
002 Tray1 0.34mm
003 Tray2 0.34mm
004 Duplex 0.34mm
[Temp. Adj.] Temperature Adjustment
1105
Adjusts the fusing unit subtractive value for the target temperature of each paper type.
Fusing Temp.
16: No adjustment
15: -2°C
14: -4°C
001
13: -6°C
12: -8°C
11: -10°C
10: -12°C
9: -14°C
1159
[Fusing JAM SC] Fusing JAM SC Setting
001 Detect 0:OFF 1:ON
[Print Support]
1900
These SPs can be adjusted by UP mode.
*EGB
Adjusts the side-to-side registration for each
*EGB
mode. This SP changes the laser main scan start
position.
*EGB
[-15 to 15 / 0 / 0.34 mm /step]
*EGB
*EGB
[1 to 16 / 16 / 1 /step]
8: -16°C
7: -18°C
6: -20°C
5: -22°C
4: -24°C
3: -26°C
2: -28°C
1: -30°C
Turns on or off the fusing jam SC to detect the three
consecutive paper jams at fusing unit.
*EGB
[0 or 1 / 0 / 1 /step]
0: OFF, 1: ON