Ricoh MD-P2 Field Service Manual page 200

Table of Contents

Advertisement

6. Troubleshooting
Thermistor Error
The thermistor output is less than 0°C for 6 seconds.
• Disconnected thermistor
• Defective harness connection
541
1. Check the harness connection of the thermistor.
A
2. Replace the fusing unit.
• Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
Print Ready Temperature Error
• The heating roller temperature increase during a set time is not correct.
6
• The fusing temperature does not reach the print ready temperature within a set time after
the fusing lamp has turned on.
• Defective thermistor
• Incorrect power supply input at the main power socket
542
• Defective fusing lamp
A
1. Check the voltage of the wall outlet.
2. Replace the fusing unit
3. Replace the fusing lamp.
• Execute "SC Reset; Fusing SC" with SP5-810-001 to recover the machine after
completing the recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
198

Advertisement

Table of Contents
loading

This manual is also suitable for:

M075

Table of Contents