Ricoh MD-P2 Field Service Manual page 205

Table of Contents

Advertisement

• Wrong engine board installed
• Wrong controller board installed
1. Check the type of EGB and controller board.
2. Replace the EGB.
3. Replace the controller board.
SC8xx
816
Energy save I/O subsystem error
D
An error was detected in the signal from the ASIC (controller board) which controls the STR
(Suspend to RAM) function.
Note: STR is a feature of this machine that minimizes energy consumption while the machine
is in the energy saver mode.
• Reboot the machine.
• Replace the controller board.
SCS
-5
Machine attempted to enter STR mode before engine is OFF.
Sub System
-39
Error occurred during system start up.
Hardware
-50
Printer version only. Not used for this machine.
-67 NCS (Network Control Service)
An error occurred in the access control port list:
• Number of registrations exceeded 125
• Data notifications exceeded 12
• Data extension incorrect
Sub System
-79
Message mismatch.
SC Conditions
6
203