Ricoh MD-P2 Field Service Manual page 114

Table of Contents

Advertisement

5. System Maintenance Reference
002 Lockout Threshold
003 Cancel On/Off
5
004 Cancel Time
5414
[Access Mitigation]
001 Mitigation On/Off
002 Mitigation Time
5415
[Password Attack]
001 Permission Number
002 Detect Time
112
Sets a limit on the frequency of lockouts for
account lockouts.
*CTL
[1 to 10 / 5 / 1/step]
Determines whether the system waits the
prescribed time for input of a correct user ID and
password after an account lockout has occurred.
[0 or 1 / 0 / -]
*CTL
0: Off (no wait time, lockout not cancelled)
1: On (system waits, cancels lockout if correct
user ID and password are entered.
Determines the length of time that the system waits
for correct input of the user ID and password after
a lockout has occurred. This setting is used only if
*CTL
SP5413-3 is set to "1" (on).
[1 to 999 / 60 / 1 min./step]
Switches on/off masking of continuously used IDs
and passwords that are identical.
*CTL
[0 or 1 / 0 / -]
0: Off, 1: On
Sets the length of time for excluding continuous
access for identical user IDs and passwords.
*CTL
[0 to 60 / 15 / 1 min./step]
Sets the number of attempts to attack the system
with random passwords to gain illegal access to
*CTL
the system.
[0 to 100 / 30 / 1 attempt/step]
Sets the time limit to stop a password attack once
such an attack has been detected.
*CTL
[1 to 10 / 5 / 1 sec./step]