A-6-8
Advanced Function Setting Level
Parameters
Characters
init
Parameter Initialization
pend
Program End ON Time
s-u
Standby Time Unit
rest
Standby Sequence
Reset
sb1n
Auxiliary Output 1
Open in Alarm
sb2n
Auxiliary Output 2
Open in Alarm
sb3n
Auxiliary Output 3
Open in Alarm
sb4n
Auxiliary Output 4
Open in Alarm
hbu
HB ON/OFF
hbl
Heater Burnout Latch
hbh
Heater Burnout
Hysteresis
α
alfa
tidu
Integral/Derivative
Time Unit
at-g
AT Calculated Gain
at-h
AT Hysteresis
lcma
Limit Cycle MV
Amplitude
inf
Input Digital Filter
mav
Moving Average Count
ret
Automatic Display
Return Time
brgt
Display Brightness
a1lt
Alarm 1 Latch
a2lt
Alarm 2 Latch
a3lt
Alarm 3 Latch
a4lt
Alarm 4 Latch
prlt
Move to Protect Level
Time
cjc
Cold Junction
Compensation Method
a1on
Alarm 1 ON Delay
a2on
Alarm 2 ON Delay
a3on
Alarm 3 ON Delay
a4on
Alarm 4 ON Delay
a1of
Alarm 1 OFF Delay
a2of
Alarm 2 OFF Delay
a3of
Alarm 3 OFF Delay
a4of
Alarm 4 OFF Delay
mant
Manual Output Method
Manual MV Initial Value mani
rt
RT
E5@C-T Digital Temperature Controllers User's Manual (H185)
Setting (monitor) value
OFF, FACT
ON: Continue output, 0.0: No output, or 0.1 to 10.0
H-M: Hours and minutes
M-S: Minutes and seconds
Condition A, condition B
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
N-O: Close in alarm
N-C: Open in alarm
OFF, ON
OFF, ON
0.1 to 50.0
0.00 to 1.00
1, 0.1
0.1to 10.0
Temperature input: 0.1 to 999.9
Analog input: 0.01 to 9.99
5.0 to 50.0
0.0 to 999.9
OFF, 2, 4, 8, 16, or 32
OFF, 1 to 99
1 to 3
OFF, ON
OFF, ON
OFF, ON
OFF, ON
1 to 30
OFF, ON
0 to 999 (0: ON delay disabled)
0 to 999 (0: ON delay disabled)
0 to 999 (0: ON delay disabled)
0 to 999 (0: ON delay disabled)
0 to 999 (0: OFF delay disabled)
0 to 999 (0: OFF delay disabled)
0 to 999 (0: OFF delay disabled)
0 to 999 (0: OFF delay disabled)
HOLD or INIT
−5.0 to 105.0 for standard control
−105.0 to 105.0 for heating/cooling control
OFF, ON
Display
off, fact
on, 0.0, or
0.1 to 10.0
h-m
m-s
a, b
n-o, n-c
n-o, n-c
n-o, n-c
n-o, n-c
off, on
off, on
1, 0.1
off, 1 to 99
off, on
off, on
off, on
off, on
off, on
hold, init
*1
*1
off, on
A Appendices
Default
Unit
OFF
None
0.0
Seconds
Hours and
None
minutes
Condition A
None
N-O
None
N-O
None
N-O
None
N-O
None
ON
None
OFF
None
0.1
A
0.65
None
1
Second
Standard
None
Model: 0.8
Position-pro
portional
Model: 1.0
0.8 (for °C)
°C or °F
1.4 (for °F)
0.20
%FS
20.0
%
0.0
Second
Times
OFF
OFF
Second
3
None
OFF
None
OFF
None
OFF
None
OFF
None
3
Second
ON
None
0
Second
0
Second
0
Second
0
Second
0
Second
0
Second
0
Second
0
Second
HOLD
None
0.0
%
OFF
None
A - 27
A