Omron E5AC-T User Manual page 414

E5xc-t series digital temperature controllers programmable type
Hide thumbs Also See for E5AC-T:
Table of Contents

Advertisement

Parameters
Characters
alt4
Alarm 4 Type
alh4
Alarm 4 Hysteresis
Control Output 1 Signal o1st
o2st
Control Output 2 Signal
trst
Transfer Output Signal
tr-t
Transfer Output Type
tr-h
Transfer Output Upper
Limit
tr-l
Transfer Output Lower
Limit
ev-1
Event Input
Assignment 1
ev-2
Event Input
Assignment 2
ev-3
Event Input
Assignment 3
ev-4
Event Input
Assignment 4
E5@C-T Digital Temperature Controllers User's Manual (H185)
Setting (monitor) value
Same as Alarm 1 Type except that 12 (LBA) cannot
be set.
Temperature input: 0.1 to 999.9 for all alarms except
for MV absolute-value upper-limit or MV lower-limit
alarms
Analog input: 0.01 to 99.99 for all alarms except for
MV absolute-value upper-limit or MV lower-limit
alarms
0.01 to 99.99 for MV absolute-value upper-limit or
MV lower-limit alarms
4-20: 4-20 mA
0-20: 0-20 mA
4-20: 4-20 mA
0-20: 0-20 mA
4-20: 4-20 mA
1-5V: 1-5 V
OFF:
OFF
SP-M: Present SP
PV:
Process value
MV:
MV (heating) (Not supported for
Position-proportional Models.)
CMV: MV (cooling) (Supported only for
heating/cooling control.)
V-M:
Valve opening (Supported only for
Position-proportional Models.)
*1
*1
NONE: None
RR-1: Run (OFF)/Reset (ON)
RR-2: Run (ON)/Reset (OFF)
MANU: Auto/Manual Switch
RST: Reset
RUN: Run
HLD1: Hold/clear hold
HLD2: Hold
ADV: Advance
PRG0: Program number switch 0
PRG1: Program number switch 1
PRG2: Program number switch 2
DRS: Invert Direct/Reverse Operation
SPM: Program SP Mode/Fixed SP Mode
AT-2: 100% AT Execute/Cancel
*2
AT-1: 40% AT Execute/Cancel
ATA2: All PID 100% AT execute/cancel
ATA1: All PID 40% AT execute/cancel
WTPT: Setting Change Enable/Disable
CMWT: Communications Writing Enable/Disable
LAT: Alarm Latch Cancel
WAIT: Wait enable (ON)/disable (OFF)
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
Same as Event Input Assignment 1.
Display
4-20, 0-20
4-20, 0-20
4-20, 1-5V
off
sp-m
pv
mv
c-mv
v-m
none
rr-1
rr-2
manu
rst
run
hld1
hld2
adv
prg0
prg1
prg2
drs
spm
at-2
at-1
ata2
ata1
*2
wtpt
cmwt
lat
wait
Same as
Event Input
Assignment 1.
Same as
Event Input
Assignment 1.
Same as
Event Input
Assignment 1.
A Appendices
Default
Unit
2
None
°C or °F
0.2
0.02
%FS
0.50
%
4-20
None
4-20
None
4-20
None
OFF
None
*1
*1
*1
*1
RR-1
None
ADV
None
NONE
None
NONE
None
A - 25
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5ec-tE5cc-t

Table of Contents