Omron E5AC-T User Manual page 127

E5xc-t series digital temperature controllers programmable type
Hide thumbs Also See for E5AC-T:
Table of Contents

Advertisement

4 Basic Operation
Setting Example
The following example shows how to set 50.
Operating Procedure
1
Specify a segment number for the Display Segment Selection
parameter and press the M Key several times to select the
Segment SP parameter.
2
Press the U or D Key to set 50 (50°C).
The default is 0.
Setting the Segment Slope Parameter (for Rate of Rise
Programming)
This parameter sets the segment slope for the specified segment number.
Related Parameters
Parameter name
Segment n Slope
Setting Example
The following example shows how to set 2.
Operating Procedure
1
Press the M Key several times from the Display Segment
Selection parameter to select the Segment 1 Slope parameter.
2
Press the U or D Key to select 2.
The default is 0.
Setting the Segment Time
This parameter sets the segment time for the specified segment number.
Related Parameters
Parameter name
Segment n Time
*The unit is set in the Program Time Unit parameter (default: h-m (hours and minutes))
4 - 42
Display
Setting range
pr
0 to 9999
Display
Setting range
time
0.00 to 99.59
Program Setting Level
Unit
Default
EU/Time Unit
0
of Ramp Rate
Program Setting Level
Unit
Default
Hours and minutes, or
0.00
minutes and seconds*
E5@C-T Digital Temperature Controllers User's Manual (H185)
sp
Segment 0
0
set point
sp
50
Level
Program Setting
Level
pr
Segment 1
0
Slope
pr
2
Level
Program Setting
Level

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5ec-tE5cc-t

Table of Contents