Omron E5AC-T User Manual page 358

E5xc-t series digital temperature controllers programmable type
Hide thumbs Also See for E5AC-T:
Table of Contents

Advertisement

out1
out2
• These parameters set the function to assign to control outputs 1 and 2.
Function
Setting
If c-o is assigned for standard control, a value equivalent to 0% is output.
*1
*2
Can be selected for relay and voltage outputs (for driving SSR) only.
*3
WR1 to WR8 are not displayed when the logic operation function is not used.
*4
If the Standard or Heating/Cooling parameter is set to heating/cooling control, control
automatically switches to c-o.
E5@C-T Digital Temperature Controllers User's Manual (H185)
Control Output 1 Assignment
Control Output 2 Assignment
Setting range
none:
Disabled
o:
Control output (heating)
c-o:
Control output (cooling)
alm1:
*2
Alarm 1
alm2:
*2
Alarm 2
alm3:
*2
Alarm 3
alm4:
*2
Alarm 4
ha:
*2
Heater alarm
hb:
*2
HB alarm
hs:
*2
HS alarm
s.err:
*2
Input error
p.end:
Program end output
stg:
*2
Stage output
run:
*2
RUN output
ts1:
Time signal 1 output
ts2:
Time signal 2 output
alm:
Integrated Alarm
wr1:
*2*3
Work bit 1
wr2:
*2*3
Work bit 2
wr3:
*2*3
Work bit 3
wr4:
*2*3
Work bit 4
wr5:
*2*3
Work bit 5
wr6:
*2*3
Work bit 6
wr7:
*2*3
Work bit 7
wr8:
*2*3
Work bit 8
A Standard Model must be used.
A Standard Model with two control outputs must be
used.
Control Output 1 Assignment: o
Control Output 2 Assignment: none
*1
*2
*2
*2
*2
6 Parameters
Default
*4
6 - 97
6