FE PXR4 Operation Manual page 9

Micro-controller x
Table of Contents

Advertisement

Parameter
display symbol
Note 1: When a customer does not specify the settings while ordering, the following settings are selected as factory defaults.
1.800.561.8187
Parameter name
1st soak segment
Sets the 1st soak segment time.
time
2nd target SV
Sets the 2nd target SV of ramp-soak
operation.
2nd ramp segment
Sets the 2nd ramp segment time.
time
2nd soak segment
Sets the 2nd soak segment time.
time
3rd target SV
Sets the 3rd target SV of ramp-soak
operation.
3rd ramp segment
Sets the 3rd ramp segment time.
time
3rd soak segment
Sets the 3rd soak segment time.
time
4th target SV
Sets the 4th target SV of ramp-soak
operation.
4th ramp segment
Sets the 4th ramp segment time.
time
4th soak segment
Sets the 4th soak segment time.
time
5th target SV
Sets the 5th target SV of ramp-soak
operation.
5th ramp segment
Sets the 5th ramp segment time.
time
5th soak segment
Sets the 5th soak segment time.
time
6th target SV
Sets the 6th target SV of ramp-soak
operation.
6th ramp segment
Sets the 6th ramp segment time.
time
6th soak segment
Sets the 6th soak segment time.
time
7th target SV
Sets the 7th target SV of ramp-soak
operation.
7th ramp segment
Sets the 7th ramp segment time.
time
7th soak segment
Sets the 7th soak segment time.
time
8th target SV
Sets the 8th target SV of ramp-soak
operation.
8th ramp segment
Sets the 8th ramp segment time.
time
8th soak segment
Sets the 8th soak segment time.
time
Ramp-soak mode
Selects the power-on start, repeat, and
standby functions for ramp-soak
operations.
Thermocouple input: Thermocouple K
Resistance bulb input:
Voltage/Current input:
www.
Note: The parameters for which * is marked with the page number in
Description
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
Within the SV limit. (*: 0%FS)
0 to 99h59m (*: 0.00)
0 to 99h59m (*: 0.00)
0 to 15 (*: 0)
Measured range: 0 to 400°C
Measured range: 0 to 150°C
Scaling: 0 to 100%
.com
Reference page are related to Remedies of "4" on page 79.
Setting range and factory
default setting (*)
information@itm.com
User's
Parameter
Reference
set value
mask DSP
page
dSP6-32
50
dSP6-64
*
50
dSP6-128
50
dSP7-1
50
dSP7-2
*
50
dSP7-4
50
dSP7-8
50
dSP7-16
*
50
dSP7-32
50
dSP7-64
50
dSP7-128
*
50
dSP8-1
50
dSP8-2
50
dSP8-4
*
50
dSP8-8
50
dSP8-16
50
dSP8-32
*
50
dSP8-64
50
dSP8-128
50
dSP9-1
*
50
dSP9-2
50
dSP9-4
50
dSP9-8
50
9

Hide quick links: