Operations

This chapter explains how to set the SV (Setting value) and the parameters for the PXR.

2-1 Parameter list

Parameters for the PXR are classified into operation parameters, and the first block, the second block and the third block
parameters according to the frequency of use. The second and the third block parameters are used at initialization or when
they are absolutely necessary.
Operation parameter
Parameter
Parameter name
display symbol
(PV)
(SV)
Parameters of the first block
Parameter
Parameter name
display symbol
1.800.561.8187
Note: The parameters for which * is marked with the page number in Reference page are related to Remedies of "4" on page 79.
Measured temperature
Displays the currently measured temperature
(Measurement value)
(Measurement value).
Set temperature
Displays the set temperature (Set value).
(Set value)
Description
Manual mode
Switches between Auto and Manual operation
selection
modes.
Standby setting
Switches between RUN and Standby for
control.
Remote/local
Switches between remote and local operations.
setting
Ramp-soak
control
Alarm latch
Cancels the alarm latch.
cancel
Auto-tuning
Used for setting the constants for , , and
by auto-tuning.
Timer 1 display
Displays the remaining time of timer 1.
Timer 2 display
Displays the remaining time of timer 2.
Timer 3 display
Displays the remaining time of timer 3.
Set value of
Sets the value at which
alarm 1
alarm 1 is detected.
Lower limit
Sets the lower limit value at
value of alarm 1
which alarm 1 is detected.
Upper limit
Sets the upper limit value at
value of alarm 1
which alarm 1 is detected.
Set value of
Sets the value during which
alarm 2
alarm 2 is detected.
Lower limit value
Sets the lower limit value at
of alarm 2
which alarm 2 is detected.
Upper limit value
Sets the upper limit value at
of alarm 2
which alarm 2 is detected.
Set value of
Sets the value at which
alarm 3
alarm 3 is detected.
Lower limit value
Sets the lower limit value at
of alarm 3
which alarm 3 is detected.
Upper limit value
Sets the upper limit value at
of alarm 3
which alarm 3 is detected.
Specifies whether or not to allow the change of
parameters.
www.
Setting range and
Description
factory default setting (*)
Setting not allowed.
0 to 100%FS (*: 0%FS)
factory default setting (*)
oN: Manual mode
oFF: Auto mode*
oN: Control standby
(Output: OFF, Alarm: OFF)
oFF: Control RUN*
rEM: Remote
LoCL: Local
oFF: Stop*
rUn: Start
HLd: Hold
0: Keeps the alarm latch.*
1: Opens up the alarm latch.
0: OFF (Resets the auto-tuning or does
not use it.)*
1: ON (Performs the auto-tuning in the
SV standard type.)
2: ON (Performs the auto-tuning in
low PV type (SV value-10%FS).)
- (Unit: seconds)
- (Unit: seconds)
- (Unit: seconds)
When the alarm type is absolute value:
is displayed
when alarm type 1
0 to 100%FS (*:10)
is 0 to 15, or 32 to
When the alarm type is deviation:
34, and
or
-100 to 100%FS (*:10)
is displayed
when alarm type 1
is 16 to 31.
is displayed
When the alarm type is absolute value:
when alarm type 2 is 0
0 to 100%FS (*:10)
to 15 or 32 to 34, and
or
is
When the alarm type is deviation:
displayed when alarm
-100 to 100%FS (*:10)
type 2 is 16 to 31.
When the alarm type is absolute value:
is displayed
when alarm type 3 is 0
0 to 100%FS (*:10)
to 15 or 32 to 34, and
or
is
When the alarm type is deviation:
displayed when alarm
-100 to 100%FS (*:10)
type 3 is 16 to 31.
0: All settings are changeable both from
the face panel and via communication.*
1: All settings are unchangeable from the
face panel, but changeable via
communication.
2: Only the SV is changeable from the
face panel, and all settings are
changeable via communication.
3: All settings are changeable from the
face panel, but unchangeable via
communication.
4: All settings are unchangeable from the
face panel or via communication.
5: Only the SV is changeable from the
face panel, but all settings are unchangeable
.com
via communication.
Parameter
mask DSP
dP13-64
See page 78 for the method
of turning on/off PV.
Mask not
14
allowed.
User's
Setting range and
set value
information@itm.com
Reference
page
Parameter
Reference
mask DSP
page
15
dP13-32
16
dSP1-1
17
dp13-8
18
dSP1-2
19
dSP1-4
20
dSP1-8
21
dSP1-16
21
dSP1-32
21
dSP1-64
*
22
dSP1-128
*
22
dSP2-1
*
22
dSP2-2
*
22
dSP2-4
*
22
dSP2-8
*
22
dSP2-16
*
22
dSP2-32
*
22
dSP2-64
*
22
dSP2-128
dSP3-1
23
7