Hysteresis Range For On/Off Control - FE PXR4 Operation Manual

Micro-controller x
Table of Contents

Advertisement

[Description]
• To select the ON/OFF control (two-position control), set
to 0.0. It is not necessary to set
• When the hysteresis range (Range of ON/OFF control) is
too small, the output may switch the ON/OFF frequently.
(This may affect the life of the device to be controlled,
especially when contact output is selected.)
• The unit of the set value of this parameter is °C or °F
(engineering unit). The setting range varies according to
the measured range of input.
[Setting example] Changing the hysteresis range from 1˚C to 35˚C
Display
1.800.561.8187
Hysteresis range for ON/OFF control (Setting range: 0 to 50%FS)
and
1.
Press and hold the
will be displayed on the PV display.
2.
Press the
key to display
3.
Press the
key once.
SEL
The current setting ( ) flashes on the SV display.
4.
Press the
or
5.
Press the
key once.
SEL
controller will operate with the hysteresis range being 35˚C.
6.
If you want to display the operation status, press and hold the
www.
[Ex] Input Thermocouple K : At measured range of 0
.
Related parameters:
Operating procedure
SEL
key for three seconds.
.
keys to display
.
will stop flashing and will be registered for
.com
to 400 °C, the setting
range is 0 to 200 °C.
Resistance bulb
: At measured range of 0
to 150 °C, the setting
range is 0 to 75 °C.
(page 24)
(page 36)
. After that, the
key for two seconds.
SEL
information@itm.com
27