FE PXR4 Operation Manual page 10

Micro-controller x
Table of Contents

Advertisement

Parameters of the third block
Parameter
Parameter name
display symbol
Control action
SV (Setting value)
lower limiter
SV (Setting value)
upper limiter
Delay time 1
Delay time 2
Delay time 3
Current transe display
HB (Set value of heater
break alarm) setting
Alarm 1 hysteresis
Alarm 2 hysteresis
Alarm 3 hysteresis
Alarm 1 options
Alarm 2 options
Alarm 3 options
Lower limit for output 1
Upper limit for output 1
Lower limit for output 2
Upper limit for output 2
Output limit types
Output value (MV)
display
Output value (MV)
display
RCJ (Cold junction
compensation)
setting
PV gradient
User-definable zero
adjustment
User-definable span
adjustment
DI1 (Digital input 1)
operation
DI2 (Digital input 2)
operation
Station No.
Parity setting
Note 2: The following settings are selected as factory defaults depending on the model you order.
1.800.561.8187
Seventh digit = Y model: 0
10
Description
Specifies control action and output at
the input burn-out.
Sets the lower limit of the SV.
Sets the upper limit of the SV.
Delay time or timer value for alarm 1 relay.
Delay time or timer value for alarm 2 relay.
Delay time or timer value for alarm 3 relay.
Displays the current detector input value for HB alarm.
Sets the operation value that detects the
heater break.
Sets the hysteresis range of ON and
OFF of alarm 1.
Sets the hysteresis range of ON and
OFF of alarm 2.
Sets the hysteresis range of ON and
OFF of alarm 3.
Sets the optional functions of alarms 1, 2 and
3.
Alarm latch (1: use, 0: not use)
Alarm of error status (1: use, 0: not use)
De-energized output (1: use, 0: not use)
Sets the lower limit for output 1.
Sets the upper limit for output 1.
Sets the lower limit for output 2.
Sets the upper limit for output 2.
Sets the limit types of outputs 1 and 2
(breaking the limit, or maintained
within the limit).
Displays the value of output 1.
Displays the value of output 2.
Sets the cold junction compensation
function to ON/OFF.
Shifts the zero point of input value.
Shifts the span of input value.
Sets the DI1 operations.
Sets the DI2 operations.
Sets the station No. for
communication.
Sets the parity for communication.
(The baud rate is fixed at 9600bps.
Seventh digit = A model: 4
www.
Note: The parameters for which * is marked with the page number in
Reference page are related to Remedies of "4" on page 79
Setting range and factory
default setting (*)
0 to 19 (*: specified by customer while
ordering)
Note 2
0 to 100%FS (*: 0%FS)
0 to 100%FS (*: 100%FS)
0 to 9999 seconds (*: 0)
0 to 9999 seconds (*: 0)
0 to 9999 seconds (*: 0)
-
0 to 50.0A (Setting to 0.0A turns off the
HB alarm.) (*: 0.0)
0 to 50%FS (*: 1)
0 to 50%FS (*: 1)
0 to 50%FS (*: 1)
000 to 111 (*: 000)
000 to 111 (*: 000)
000 to 111 (*: 000)
-3.0 to 103.0% (*: -3.0)
-3.0 to 103.0% (*: 103.0)
-3.0 to 103.0% (*: -3.0)
-3.0 to 103.0% (*: 103.0)
0 to 15 (*: 0)
-
-
ON: Performs the RCJ (Cold junction
compensation).*
OFF: Does not perform the RCJ (Cold
junction compensation).
0.001 to 2.000 (*: 1.000)
-50 to 50%FS (*: 0)
-50 to 50%FS (*: 0)
0 to 12 (*: 0=OFF)
0 to 12 (*: 0=OFF)
0 to 255 (Setting to
does not start the
communications function.) (*: 1)
0: Odd parity*
1: Even parity
2: No parity
.com
User's
Parameter
Reference
set value
mask DSP
dSP9-16
dSP9-32
dSP9-64
dSP9-128
dP10-1
dP10-2
dP10-4
dP10-8
dP10-16
dP10-32
dP10-64
dP10-128
dP11-1
dP11-2
dP11-4
dP11-8
dP11-16
dP11-32
dP11-64
dP11-128
dP12-1
dP12-2
dP12-4
dP12-8
dP12-16
dP12-32
dP12-64
dP12-128
dP13-1
information@itm.com
page
53
*
54
*
54
55
55
55
57
57
*
59
*
59
*
59
60
60
60
62
62
62
62
63
64
64
65
*
66
*
66
67
67
70
71

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for FE PXR4

This manual is also suitable for:

Pxr9Pxr5Pxr7

Table of Contents